Jarua
Installation and maintenance of your towel rail
E
2.OPERATING INSTRUCTIONS OF YOUR TOWEL RAILS
To make the most of your towel rail and for greater comfort,
we would ask you to take the following recommendations
into account:
2.1 Positioning
The diagrams below show the appliance's correct
positioning.
figure 1
figure 2
The appliance must be installed on a vertical wall and the
power cable must be located at the bottom.
• Figures 1 and 2 below show the correct positioning of the
radiator,
• The radiator should be mounted on a vertical wall with the
connection cord at the bottom of the radiator,
• The lower part of the radiator must be within a minimum
distance of 150 mm from the ground,
• The radiator must not be installed within 50 mm of a wall
or underneath a power outlet,
• Improper installation of a shelf above the radiator must be
carried out over 150 mm of it,
• It is recommended to perform the installation, if possible,
close to locations with high heat losses (windows etc) and
using screw fasteners appropriate to the nature of the
wall,
• Drill and plug the 4 fixing holes in a suitable location,
• Secure the radiator to the wall using the screws supplied,
• Make the electrical connection.
12
M16MI316_A08_07/21
2.2 xations
2.2 Brackets
For the correct installation of radiators it is
essential that the fixing of the radiator is carried
out in such a way that it is suitable for intended
use AND predictable misuse.
A number of elements need to be taken into
consideration including the fixing method used to
secure the radiator to the wall, the type and
condition of the wall itself, and any additional
potential forces or weights that may happen to
be applied to the radiator, prior to finalising
installation.
• For correct heater installation, when the appliance is
located close to a wall, it is essential to leave a minimum
distance of 250 mm to access the installation.
• Use bracket screws suited to your type of wall, secure the
heater on the wall using the screws provided with the
towel rails.
• The towel rail must be installed on a vertical wall using
the wall mounts supplied.
• The towel rails' mounting components are adjustable
vertically, horizontally and as regards depth (see
exploded diagram in the box), which makes correct
installation easier. Positioning can be seen from
the figure on the drawing page.