MOUNTING AND CONNECTING

Mounting and Connecting

Connection Examples

INSTALLATION
1. Loosen the three screws of the back cover with a 3 mm Allen key. We recommend
for easier access to the screws to push the sunshield forward.
2. Push the body forward for the access to the terminal strip.
3. Make the electrical connections ensuring that they are electrically safe.
4. Before closing the housing, do not forget to connect the earth wires of the body to
the pin connector provided inside the housing.
5. Close the housing
6. In case not all the glands are used, insert in the exceeding gland a plastic cap we
supply as standard and tighten the lock nut to guarantee the IP67 protection rating.
INSTRUCTIONS FOR THE ASSEMBLY OF
THE BRACKET
♦ Position the bracket (1) as indicated on the
drawing and insert the cover (2) into the
upper hole, the joint (3) and the spherical
pin (4)
♦ Screw the screw (5) to the bottom of the
spherical pin (4), without tightening the
screw.
♦ Rotate the pin (4) until the slot (6) fits in the
mark (7) placed on the bottom of the brack-
et.
♦ Tighten the screw. (5)