5. Replacing the hose and pressure regulator
Replace your propane gas hose every three years. This is a national advice. Pressure regulators can go for five
years. After the pressure regulator and the gas hose have been replaced, the unit must always be checked for
gas leaks. How to check your built in burner for gas leaks:
-
Open the gas bottle but do not turn on the burner!
-
Make a solution with 50% water and 50% detergent, and spray this solution on each connection and the
hose. If there is a gas leak in the connection or the hose you will see air bubbles arise.
-
If bubbles are visible, immediately shut off the gas. Buy a new hose or regulator.
-
Does the problem keep occurring? Please contact a qualified gas engineer.
Replace the hose or pressure regulator and make sure that they are installed in the exact same way. In the
Netherlands, a 30mbar pressure regulator should be placed. The hose must not be longer than 2.5 meters.
When in doubt, always consult a qualified gas engineer.
6. Replacing the battery for the piezo ignition
The Build up burner features a piezo ignition that runs on one AAA battery. This battery may run out after
repeated use of the device. The battery can be replaced as follows :
-
Make sure the model, ceramic logs and lava rocks are completely cooled down.
-
Make sure the Build up burner is no longer connected to the gas bottle.
-
The left knob on the control panel, there is the ignitor, the battery is in the black capsule.
-
You can now twist the black ignition open and place the battery on the ignition, according to the
instructions. Please mind the +/- sides.
-
The old battery should be returned to a collection point.
7. Moving the unit
It is advisable to move the Cosiburner as little as possible. With every move you risk damage to Cosiburner. If
you still want to move the unit, make sure that the burner is shut off from the gas bottle. The new location for
Cosiburner needs to be clean, flat and hardened again.