Display Screen
The handset surface is a button panel. If no button is pressed within 30 seconds, the screen
auto-locks and the corresponding 1/2/3/4/S keys are locked. Press Up or Down key to activate the
display screen again.
Display screen
Displays the height of the desk.
Up & Down keys
Press UP/DOWN key to adjust desk height until you reach optimal position.
Memory keys 1/2/3/4
After setting the memory keys, the desk raises automatically to the set memory height.
How to set memory mode
Press the "S" key when running to a specific point. The display screen displays "S-" and "-" flashes.
Now press "1-4" keys to save the position at the corresponding height. The memory height is now
saved. Press 1/2/3/4 lightly. The desk raises/lowers to memory height automatically.
Set Key (S)
Press the "S" key when memory and internal parameters need to be set.
Initialization
1. When "RST" appears on the screen, press the "↓"button until the desk frame reaches its lowest
point. After hearing the beep and desk frame rebounds, initialization is completed.
(Note! Hold the button down during the whole operation or the initialization will not be completed)
2. Forced initialization: Press the "↓" button until the desk frame reaches its lowest point, then release
the button and press it again for about 5 seconds until you hear the beep and desk frame rises
slightly. The initialization is complete.
3. Restore the factory settings: When a new controller is used or the parameters need to be restored
to the factory settings, press the "↓" and "↑" buttons simultaneously. You will hear the first beep after
about 5 seconds and second beep sound after 10 seconds. When the display screen shows "RST",
please follow the operating instructions in item 1.
Safety Function
Resistance will stop the desk's raising or lowering motion.
Handset shows error code and solution
Error code
E1, E6, E7
E2
E4
E5
E8
E11, E21
E12, E22
E14~E17, E24~E27
E18, E28
HOT
EN
DIRECTIONS FOR USE
Up & Down key
Cause of error
power error
non-synchronous height over 1 cm
handset malfunction
Anti-collision alert
desktop sloping
Motor defect
controller fault
motor error
overload
Overheating
10 (11)
34/147
Memory key
Set key
Solution
change power source
Implement the initialization operation 1
Unplug and replug the cable of hand set
Rebound reminder, normal condition
check the desktop
inspect the motor wire
change the controller
change motor
reduce the load
Stops. Automatic recovery after 20 minutes