Herunterladen Inhalt Inhalt Diese Seite drucken

Hitachi Koki CM 7MRU Bedienungsanleitung Seite 12

Mauernutfräse
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13
English
NOTE
Due to HITACHI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
IMPORTANT
Correct connection of the plug
The wires of the mains lead are coloured in accordance
with the following code:
Blue:
–Neutral
Brown:
–Live
As the colours of the wires in the mains lead of this
tool may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
The wire coloured blue must be connected to the
terminal marked with the letter N or coloured black.
The wire coloured brown must be connected to the
terminal marked with the letter L or coloured red.
Neither core must be connected to the earth terminal.
NOTE
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not be
applicable to other markets except the United Kingdom.
Information concerning airborne noise and vibration
The measured values were determined according to
EN60745 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 110 dB (A).
Measured A-weighted sound pressure level: 99 dB (A).
Uncertainty KpA: 3 dB (A).
Wear hearing protection.
Vibration total values (triax vector sum) determined
according to EN60745.
Vibration emission value
2
Uncertainty K = 1.5 m/s
WARNING
The vibration emission value during actual use of
the power tool can differ from the declared value
depending on the ways in which the tool is used.
To identify the safety measures to protect the
operator that are based on an estimation of exposure
in the actual conditions of use (taking account of
all parts of the operating cycle such as the times
when the tool is switched off and when it is running
idle in addition to the trigger time).
11
a
2
h = 7.4 m/s
Information about power supply system of nominal
voltage 230 V~ (For CM7MR • CM7MC)
Under unfavorable mains conditions, this power tool may
cause transient voltage drops or interfering voltage
fluctuations .
This power tool is intended for the connection to a power
supply system with a maximum permissible system
impedance Z
of 0.28 Ohm (CM7MC: 0.23 Ohm) at the
MAX
interface point (power service box) of the user's supply.
The user has to ensure that this power tool is connected
only to a power supply system which fulfills the
requirement above.
If necessary, the user can ask the public power supply
company for the system impedance at the interface point.