Herunterladen Inhalt Inhalt Diese Seite drucken

IFM Electronic ecomot200 400 Serie Betriebsanleitung Seite 11

Elektronischer zähler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Programming
The following parameters can be set (3rd column: basic setting):
counting function
0 = VRD (up / down differential; electronic and mechanical
P01
pulse pick-ups)
1 = VR (up / down; incremental shaft encoders)
control inputs for electronic or mechanical pulse pick-ups
P02
0 = pnp switching
1 = npn switching
decimal places
P03
0 ... 3 = 0 ...3 decimal places after the point
last value memory
0 = last value memory active
P04
(on power up the last value is displayed)
1 = last value memory not active
(on power up the preset value is displayed)
front reset
P05
0 = front reset active
1 = front reset not active
edge evaluation
0 = one-fold evaluation
P06
1 = two-fold evaluation
2 = four-fold evaluation
change of signs
P07
0 = change of signs active
1 = change of signs not active
multiplication factor
multiplication of the input pulses by factor
P08
0.0001 ... 9.9999
(if P11 is set to 4 or 5, only factors ≤ 1.0000 should be
used)
relay function
0 0 = H1 and H2 fleeting
P10
0 1 = H1 solid state, H2 fleeting
1 0 = H1 fleeting, H2 solid state
1 1 = H1 and H2 solid state
All manuals and user guides at all-guides.com
11
1
0
0
0
0
0
0
1,0000
0 0

Werbung

Inhaltsverzeichnis
loading