Type of Malfunction / Cause
• Air system does not function
• Hydro system function insufficient
• Hydro system does not function
• System switches itself on without an
obvious reason
• Water nozzle
Leakage:
• air
• Water underneath the tub
• Underwater lighting does not switch on
All manuals and user guides at all-guides.com
english
Possible Cause
• Check you have an electricity supply?
− Malfunction in electrical mains
− Are the plug connections to the
control correctly seated?
• Control does not react
• Control defective
• Control element defective
• Blower defective
• Filter at intake socket is blocked
• Nozzle dirty
• Is voltage applied?
− Malfunction in electrical mains
− Are the plug connections to the
control correctly seated?
• Is the water level high enough?
• Water level sensor does not react
• Control does not react
• Control defective
• Control element defective
• Hydraulic pump defective
• Automatic cleaning function of the air
nozzles
• Has the room temperature changed
(e.g. floor heating underneath the
whirlpool)
• Has the humidity in the room changed
(e.g. use of a shower in the same room)
• Were cables, water pipes or other
electrically conductive materials laid in
the area of the water level sensor?
• Is/was cleaning work performed near
the tub? (e.g. moist cleaning cloth near
the water level sensors)
• Nozzle dirty
• Nozzle head not adjustable
− is seized
− is loose
• Air hose loosened on:
− Blower
− Air distributor
− Air nozzle
• Hydro hose loose on:
− Pump
− Hydro nozzles
• Drain/overflow defective?
• Seals on nozzles leaking?
• Acrylic material damaged?
• Tub inflow connection leaking?
• Is the water level high enough?
• Lighting element defective?
• Is voltage applied?
− Malfunction in electrical mains
− Are the plug connections to the
control correctly seated?
• Water level sensor does not react
sTÖRunGen unD ABhILfe
TRouBLe shooTInG
RIsoLuzIone DeI PRoBLeMI
Possible Clearance
− Call electrician
− Pull and reinsert plug
• Reconfigure Poolmaster
• Replace control
• Replace control element
• Replace blower
• Remove cover at intake socket and
clean filter (see service)
• Clean nozzle (see service)
− Call electrician
− Pull and reinsert plug
• Continue to fill tub
• Adjust sensor
• Replace sensor
• Reconfigure Poolmaster
• Replace control
• Replace control element
• Replace hydraulic pump
• Okay
• Readjust sensitivity of the water level
sensor
• Readjust sensitivity of the water level
sensor
• Reposition cables, water pipes or similar
• Remove objects from the tub
• Clean nozzle (see service)
− Reposition O-ring behind head
− Replace O-ring behind head
• Tighten hose clamp / disconnect and
reconnect hose
• Retighten hose clamp
• Replace seals
• Replace seals
• Repair acrylic material with repair sets
• Replace seals
• Continue to fill tub
• Replace lighting element
− Call electrician
− Pull and reinsert plug
• Adjust sensor
• Replace sensor