Operating Instructions
Power pack SINEAX B 840
The following symbols in the Operating Instructions indicate
safety precautions which must be strictly observed:
The instruments must only be desposed of in
the correct way!
Contents
1. Read fi rst and then ... .................................................. 6

2. Brief description ............................................................ 6

3. Technical data ............................................................... 6

4. Mounting ....................................................................... 7
5. Electrical connections ................................................... 7
6. Commissioning and maintenance ................................. 7
7. Releasing the instrument ............................................... 7
8. Dimensional drawing ..................................................... 7
9. Declaration of conformity .............................................. 7
1. Read fi rst and then ...
The proper and safe operation of the device
assumes that the Operating Instructions is
read carefully and the safety warnings given
in the various Sections
4. Mounting
5. Electrical connections
are observed.
The device should only be handled by appropriately
trained personnel who are familiar with it and authorised
to work in electrical installations.
Unauthorized repair or alteration of the unit invalidates
the warranty!
2. Brief description
The power supply unit SINEAX B 840 provides the DC power
supply for 2-wire transmitters. There are 4 power supply
outputs available. Each power supply output is monitored by
a green LED. The corresponding green LED is continuously
lit when the measuring / supply circuit is closed.
6
All manuals and user guides at all-guides.com
3. Technical data
Input circuit (MSK)
Signal range:
Supply voltage:
Power supply
Nominal voltage:
Safety
Protection class:
Housing protection:
Terminals protection:
Rated insulation
voltage (versus earth): 230 V power supply
Pollution degree:
Installation category:
Test voltage:
Installation data
Mechanical design:
Material of housing:
Mounting position:
Mounting:
Electrical connections
Connection:
Permissible cross
section of the
connection leads:
Environmental conditions
Operating temperature: – 10 to + 55 °C
Storage temperature:
Relative humidity of
annual mean:
Altitude:
Indoor use statement!
4 ... 20 mA
with 2-wire transmitter
Input circuit 24 V DC ± 7%
Current limiter ≤ 25 mA
24 V AC, ± 10%, 50/60 Hz
115 V AC, ± 10%, 50/60 Hz
230 V AC, ± 10%, 50/60 Hz
Power input
≤ 10 VA with 4 outputs
II (protection isolated, EN 61 010)
IP 40 (test wire, EN 60 529)
IP 20 (test fi nger, EN 60 529)
40 V output
2
III
3,7 kV
Housing P13/70
Lexan 940 (polycarbonate),
fl ammability Class V-0 acc. to UL 94,
self-extinguishing, non-dripping,
free of halogen
Any
For rail mounting
Screw-type terminals with indirect
wire pressure
2
≤ 4.0 mm
single wire or
2 ×2.5 mm
2
fi ne wire
– 40 to + 70 °C
≤ 75%
2000 m max.