The HF 180 KNX is an active motion detector. It responds to the slightest
movement regardless of temperature. The integrated HF sensor emits
high-frequency electromagnetic waves (5.8 GHz) and receives their echo.
In response to the slightest movement in the detection zone, the change in
echo is perceived by the sensor. A microprocessor then issues the "switch
light ON" switching command, for example. Detection is possible through
doors, panes of glass or thin walls.
The IR 180 / HF 180 KNX also indicates the temperature and humidity levels
measured. These values are transmitted via the KNX bus.
Optionally, all function settings can be made via the RC 6, RC 7 remote controls
as well as the Smart Remote. (➜ "7� Accessories")
Package contents IR 180 KNX (Fig� 3�1)
Package contents HF 180 KNX (Fig� 3�2)
Product dimensions IR 180 / HF 180 KNX (Fig� 3�3)
Product components (Fig� 3�4)
A Rocker switch
B Cover
C IR 180 KNX lens / HF 180 KNX cover
D Removal slot
E Programming button
F Sensor module
G Status LED
H Temperature / humidity sensor
I
Surround
J Metal frame
4� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, taking the reach and motion
detection into consideration (Fig� 5�1).
Note for IR 180:
The mounting location should be at least 1 m away from any lights
because heat radiated from these may activate the system.
- 16 -
• Switch OFF power supply. (Fig� 4�1)
• Disconnect sensor module from surround. (Fig� 4�2)
• Screw on support ring with box fixing screws. (Fig� 4�3)
• Connect plug-in connectors. (Fig� 4�4)
• Switch ON power supply. (Fig� 4�6)
• Press programming button and make program settings.
(Fig� 4�5) (➜ "5� Operation")
• Fit the sensor module into the surround and press together with metal
frame (support ring).
5� Operation
Note: You will find an application description at knx�steinel�de. All factory
settings may be found in the application descriptions.
1. Issue physical address and generate application program in the ETS.
2. Load the physical address and application program into the wall switch.
When you are prompted, press the programming button (E).
3. The red LED goes out once programming has been successfully completed.
Integrated button
The button function is defined in the ETS.
6� Accessories (optional)
User remote control RC 7 (EAN 4007841 592912)
Functions:
- Light ON/OFF 4 h
- User reset
- Adjust dimming level
- Save / load scenarios
Service remote control RC 6 (EAN 4007841 593018)
Functions:
- Reach adjustment
- Time setting CH 1 / CH 2
- ON delay / room surveillance, CH 2
- Test / normal mode
- Teach-IN
- Reset
- IQ mode