Troubleshooting

The drive rotates continually without approaching a position
o Device was operated without a respective valve
Please return for repair; damage has already occurred in this case
The drive continually triggers the backwash cycle
o The system contains pressure boosting components (e.g., Solar absorbers)
Set the pressure sensor in such a way that the Loxone Aquastar Air does
not trip even at increased pressure
The pump fails to switch on or off
o Relay is burnt-out
The maximum pump current of 8A was exceeded
o The pump is not properly connected
The pump must always be looped via contacts 13-14
The disk is not lifting freely, or the drive is not running smoothly, or flow noises can be
heard
o The pump does not switch off when the valve retainer is lifted
The pump must always be looped via contacts 13-14
o The drop from the water surface to the valve is too great
Make sure that the total water column does not exceed 3m.
o The V6 valve is soiled or clogged by debris
Clean the valve and use a pre-filter