Sicherheitsventile mit bauteilprüfung federbelastet
Inhaltsverzeichnis

Werbung

We declare, that the devices
KSE, KSEA
are suitable for use in a safety related application, if the safety instructions and the following
parameters are observed:
Device Type:
Proof Test Interval:
HFT:
:
λ
SU
:
λ
SD
:
λ
DU
:
λ
DD
SFF:
PFD
:
Avg
MTBF:
Safety Integrity Level:
The speci ed values are valid only for the valve. Accessories such as an actuator, solenoid
valves, limit switches etc. are not included.
______________________________
Gregor Kleining
Dir. Research & Development
Erstellt/
:
CRQ/MP
Prepared by
Genehmigt/
:
CRQ/MP
Released by
SIL
Declaration by the Manufacturer
Functional Safety according to IEC 61508
A
≤ 1 year
0 (single channel usage)
585 FIT
65 FIT
501 FIT
149 FIT
61,4 %
-3
2,19 10
(for T
87,8 years
SIL 2
am/
: 18.03.13
on
am/
: 18.03.13
on
A Unit of IDEX Corporation
= 1 year)
Proof
______________________________
Michael Pohlmann
Quality Manager
Seite/
: 1
Page
von/
:
1
of
Kempen, 27.01.2011
QM-Nr./
: 0905-40-1049_KSE/4-01