Step 5
Connect to gas canister
Regulators will vary depending on region.
Gas Safety Information
The appliance must be installed at least 1 meter from any flammable materials.
The oven should be placed on a non-flammable, stable and flat surface.
Make sure your oven is placed in an area that will not be affected by adverse weather.
Appliance only to be used with Propane LPG. Minimum cylinder capacity 4kg maximum
cylinder capacity 13kg.
Use a suitable provided regulator certified to EN 16129 and a flexible hose certified to
EN 16436.
The length of the hose must be no more than 1.5 meters. Worn or damaged hose must
be replaced. Ensure that the hose is not obstructed, kinked, or in contact with any part of
the oven other than at its connection.
The gas supply hose should be checked periodically and should replaced if damaged and
at least every two years.
Your countries national requirements will advise you how often to replace the hose.
Regularly review these requirements for your country.
In the case of blocked venturi immediately turn off burner unit, turn off gas supply,
disconnect gas supply and wait until cooled to removed from oven.
Ensure the appliance is clear of debris before every use. If any debris does build up use a
brush to remove this when appliance has cooled.
8
Patio gas regulator
This is a push-on gas fitting. Ensure that the black switch is in the horizontal position. Depress
the button located below the black switch and press the regulator on to the tank valve until it
locks into place.
POL gas regulator
This is an anticlockwise threaded gas fitting. Ensure the tank is fully turned off and screw the
regulator on to the gas tank valve fitting until tight.