7.2 Connecting consumers to the generator
. Set the selector switch (Fig. 2/Item 11) to the
left to use 230V~ sockets.
. Set the selector switch (Fig. 2/Item 11) to the
right to activate the 400V 3~ socket.
. The generator is suitable for alternating voltage
appliances for 230 V~ and 400 V 3~.
. The generator may also be exposed to a
continuous load of 12 V DC 100 W (Fig. 2/Item
15).
. The power generator is not suitable to be
connected to the house network as a home
emergency power supply. Damage to the
generator or other electrical equipment may be
caused.
Note: Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power
consumption when used in difficult conditions
Some electrical appliances (for example
televisions, computers, etc.) should not be
powered by a generator. If in doubt, consult the
manufacturer of your appliance.
7.3 Overload cut-out
The generator is fitted with an overload cut-out.
This isolates the relevant sockets if an overload
occurs.
Important. If this happens, reduce the electric
power you are taking from the generator or
remove any defective connected appliances.
Important. Defective overload cut-outs must be
replaced only by overload cut-outs of identical
design and with the same performance data.
If repairs are necessary, please contact your
customer service center.
12V DC connector
If an overload occurs, the 12V DC connector (Fig.
18
2/Item 15) will be isolated from the supply.
The 12V DC connector can be reconnected by
pressing the overload switch Fig. 2/Item 13).
230V~ sockets
If an overload occurs, the 230V~ sockets (Fig. 2/
Item 16) will be isolated from the supply. You
can restart the 230V~ sockets by pressing the
overload switch (Fig. 2/Item 12).
400V 3~ socket
If an overload occurs, the 400V 3~ socket (Fig.
2/Item 17) will be isolated from the supply. You
can restart the 400V 3~ sockets by pressing the
overload switch (Fig. 2/Item 10).
7.4 Switching off the engine
. Before you switch off the generator, allow it to
run briefly with no consumers so that it can "cool
down".
. Move the ON/OFF switch (Fig. 2/Item 18) to
position "OFF" using the key.
. Close the fuel cock.
Note: The engine can also be stopped by pressing
the mechanical switch (Fig. 6/Item B). Before it is
restarted in this case, the lever (Fig. 6/Item A)
must be moved back to the right until it engages.

8. Maintenance

Shut down the engine before doing any cleaning
and maintenance work on the unit.
Remove dust and dirt from the machine at
regular intervals. Cleaning is best carried out with
a fine brush or a cloth.
. Never use caustic agents to clean plastic parts.
. Take the diesel mixture out of the generator if
you do not intend to use it for a lengthy period of
time