Index
8sub9
Name
hex
0x5F
Measurement Data
Collection
1
Position value
2
Signal quality
3
BD1 Status
BD2 Status
4
5
BD3 Status
Standard operation control
Output
0x70
Configuration
1
Output Type Q1
2
reserved
3
reserved
4
Analog Output
Type UI
5
reserved
6
reserved
7
Voltage Low Value
8
Voltage High Value
16
SMW-AUTOBLOK
IO Link Prozessstruktur und Parameter
Typ
Datentyp
Wert
R
record
R
uint16
0...448
R
uint8
0x00 - insufficient / no position
acquisition possible
0x01 - acceptable
0x02 - good
0x03 - excellent
R
uint8
0: inactive
1: active
R
uint8
0: inactive
1: active
R
uint8
0: inactive
1: active
R/W
record
R/W
uint8
0x00 - push-pull
0x01 - low-side
0x02 - high-side
R/W
uint8
0x00 - reserved
0x01 - reserved
0x02 - reserved
0x03 - reserved
R/W
uint8
0x02 - reserved
0x03 - reserved
R/W
uint8
0x00 - reserved
0x01 - reserved
0x02 - reserved
0x03 - U: 0...10V
0x04 - U: 1...5V
R/W
uint8
0...200
R/W
uint8
0...200
R/W
uint8
0...100
R/W
uint8
0...100
Standard-
Einheit
wert
1/32mm
0
200
0
0.1V
100
0.1V