IO Link Prozessstruktur und Parameter
Index
sub
Name
hex
0x4000
BD3_SPV -
Switching signal 1
1
SP1 - set point
value 1
2
SP1 - set point
value 1
0x4001
BD3_SPC - Switching
signal 1 configuration
1
switchpoint logic
2
switchpoint mode
3
switchpoint
hysteresis
Device specific operation parameters
0x40
Centered Window
Width
1
BD channel 1 width
2
BD channel 2 width
3
BD channel 3 width
0x42
AD_SPC - Analog
Signal Set Point Value
1
SP1 - set point
value 1
2
SP1 - set point
value 2
AD_SPC -
0x43
Analog Signal
Configuration
1
Analog Output
Mode
2
Error Value
Hysteresis
3
Error Replacement
Value
Typ
Datentyp
Wert
R/W
record
R/W
unit16
0...448
R/W
unit16
0...448
R/W
record
R/W
uint8
0x00 - not inverted
0x01 - inverted
0x02 - 0xFF - not allowed
R/W
uint8
0x00 - inactive
0x01 - single point mode
0x02 - window mode
0x03 - two point mode
0x04 - 0x7F - reserved
0x80 - centered window mode
R/W
uint16
0: Normal
1: Medium
2: High
R/W
record
R/W
uint16
0...448
R/W
uint16
0...448
R/W
uint16
0...448
R/W
record
R/W
uint16
0...448
R/W
uint16
0...448
R/W
record
R/W
uint8
0x00 - Rising Ramp
0x01 - Falling Ramp
R/W
uint16
0: Normal
1: Medium
2: High
R/W
uint8
0b0000 0000 - disabled
0bXXXX XXX1 - out-of-range
enabled
0bXXXX XX1X - no target
enabled
Standard-
Einheit
wert
336
1/32mm
368
1/32mm
0x00
0x80
1
32
1/32mm
32
1/32mm
32
1/32mm
0
448
0x00
0
0
SMW-AUTOBLOK
15