Digits can be placed at any position in the tørpaneler beregnet til panelmontage. Operatørpa- text field. nelet kan rumme op til: UCT-30 100 meddelelser, UCT-31/35 200 og UCT-31P/35P 190 meddelelser. 1.0 ALLGEMEINE BESCHREIBUNG Hver meddelelse kan indeholde to tekstlinier à 20 karakterer.
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 2 PROGRAMMERING. 2.2 Før programmering. Tekstdisplayet programmeres enten fra et stan- Før du tilslutter forsyningsspænding til tekst- dard XT/AT-keyboard eller fra en IBM kompatibel displayet, skal tekstdisplayet tilsluttes et XT/AT- keyboard eller PC.
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 2.3 Programmering fra keyboard. 2.3.1 Opsætning. Når forsyningsspænding er tilsluttet viser tekst- Opsætningsparametrene er fælles parametre for displayet: alle meddelelser i tekstdisplayet: - Display-intensitet. TEXT DISPLAY UCT-XXX VERS. Y.YY - Karaktersæt.
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 2.3.1.2 Karaktersæt. Specialkarakterer indtastes ved holde <ALT> Der kan vælges et af følgende karaktersæt: tasten nede og indtaste den tilhørende kode på det numeriske tastatur (kun AT-keyboard). Dansk Kompatibel med ældre Karaktersættene 5-10 (CP850) supporteres ikke af...
93-02-20 11:35 BRODERSEN Brug tasterne: Alle meddelelser er programmeret fra Brodersen Control System A/S som i eksemplet ovenfor. <TAB> eller <→ → → → → > for at flytte cursoren frem. <Slet bagud> eller <← ← ← ← ← > for flytte cursoren tilbage.
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 2.3.3.1 Variable cifre. 2.3.3.2 Tid/dato cifre (kun P-version). Én meddelelse kan indeholde op til 16 variable. År, måned, dato, timer og minutter kan udlæses i displayet. Cifrene kan placeres frit i meddelel- De variable cifre kan placeres frit i meddelelsen, adskilte eller i grupper.
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 2.3.4 Gem/kopier en meddelelse. 2.3.5 Fortryd redigering af en meddelelse. Når en meddelelse er indtastet/redigeret, f.eks. Er en meddelelse er blevet redigeret og ændrin- meddelelse 078 og der er trykket <CR>/<EN- gerne ikke ønskes gemt, så...
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 2.4. Programmering fra PC. 2.4.1 PC-editor UCP-201/202. Når forsyningsspænding er tilsluttet viser tekst- PC-editoren UCP-201/202 giver dig mulighed for displayet: Indtaste og redigere meddelelser på en IBM TEXT DISPLAY kompatibel PC.
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 3.0 DRIFT. Indgangskoden skal være binær eller BCD sva- rende til indstillingen af kodeomskifteren: I drift overføres alle data mellem PLC'en og tekst- displayet via det parallelle interface. Valg af med- delelse og variable cifre repræsenteres ved bi-...
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 Ønskes kun et begrænset antal meddelelser an- Eksempel: I meddelelse nr. 005, indlæses værdi- vendt, er det kun nødvendigt at tilslutte de bety- erne 2 og 9 til ciffer 1 og 2.
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 3.4 Idec Izumi Mode (kun UCT-31/31P/35/35P). 3.4.1 4 variable cifre (switch 2: Off). Skal tekstdisplayet styres fra en Idec Izumi PLC kan Ved at bruge funktionen “FUN 147-25” i Idec Izumi det foregå...
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 3.4.2 16 variable cifre ( switch 2: On). Ved at bruge funktionen “FUN 147-25” er det muligt 0 DCBA 0111 Cifferværdien DCBA indlæses at indlæse 16 variable. Da funktionen “FUN 147- til ciffer nr.
Under initialisering sættes printeren op til det lelse vælges eller gemmes karaktersæt, som er valgt under programmering. Gyldige numre: UCT-30: 000-099 UCT-31/35: 000-199 Under drift skrives en meddelelse ud når den UCT-31P/35P: 000-189. vælges fra PLC'en. Udskriften forsinkes 0,5 eller 1,5 sekund (valgbart på...
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 Signal fra potentialfri kontakt. 6.3 Konnektor (PC/keyboard programmering). Keyboard PC 0 1 2 3 4 5 6 7 8 C - + Clock. Data Øvrige indgange tilsluttes som indgang nr. 0.
All manuals and user guides at all-guides.com Tekstdisplays/Operatørpaneler Parallelle indgange UCT-30/31/35 7.0 TEKNISKE DATA. Display: VFD-type, 2x20 karakterer, Tastatur: 4 potentialfri trykknapper med 5x7 punktmatrix. fælles terminal. Læselig på op til 3 meters afst. Belastning: Maks. 30V/20mA. Displayfelt: 125x22 mm.
Ingen Printerudgang Frekvens: 40-60Hz. Forsyningsspænding: Effektforbrug: Ca. 10W. 12-48V AC/DC. 110-240V AC. Omgivelses- temperatur: -20 til +50°C 1) UCT-30 leveres ikke med printerudgang. Tæthedsgrad: Front: IP65 Bagpanel: IP20 TILBEHØR EMC: I henhold til EN50081-1, EN50082-2. Keyboard til programmering. UCK-21 Isolation:...
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 2 PROGRAMMING. 2.2 Before Programming. The message display is programmed either from Before you connect the supply voltage to the a standard XT/AT keyboard or from an IBM com-...
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 2.3 Programming from Keyboard. 2.3.1 Set-up. When supply voltage is connected, the message The set-up parameters are common param- display shows: eters for all messages of the message display: - Display-intensity.
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 2.3.1.2 Character Set. The message display has 10 character sets to Special characters should be entered by holding select from: down the <ALT> key while entering the corre-...
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 2.3.1.3 Real-time Clock Adjustment (P-version 2.3.2 Select a Message. Select a message by entering the actual numb only). The built-in real-time clock can be adjusted by er e.g. 078. The messages are numbered 000- typing TTT 189 and all 3 digits must be entered.
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 2.3.3.1 Variable Digits. 2.3.3.2 Time/Date Digits (P-version only). Up to 16 variable digits can be contained in a Year, month, date, hour and minutes can be message. The variable digits can be placed at any displayed at any position in each message.
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 2.3.4 Save/Copy a Message. After having created/edited a message e.g. mes- Assign the printout of a message by typing 1, or sage no. 078 and having pressed <CR>/<EN- disable by typing 0, at the printer output selector TER>, the display shows:...
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 2.4. Programming from PC. 2.4.1 PC Editor UCP-201/202. When supply voltage is connected the message The PC editor UCP-201/202 lets you: display shows: Create and edit messages on an IBM com- patible PC.
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 3.0 OPERATION. In operation all data are transferred between the The inputs are to be loaded as binary or BCD PLC and the message display via the parallel codes, corresponding to the setting of the code interface.
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 If an application only requires few messages, only Example: In message number 5, the values 2 and significant inputs needs to be connected, e.g. if 9 are loaded to digit numbers 1 and 2.
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 3.4 Idec Izumi Mode (UCT-31/31P/35/35P only). 3.4.1 4 Variable Digits (Switch 2: Off). Controlling the text display from Idec Izumi PLCës Using the function ìFUN 147-25î in the Idec Izumi...
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 3.4.2 16 Variable Digits ( Switch 2: On). Using the function ìFUN 147-25î in the Idec Izumi 0 DCBA 0111 Digit value DCBA loaded to PLC, makes it possible to load variable va-lues to digit no.
TEXT DISPLAY ERROR Messages selected for print out will be printed as: Operation & Programming mode: An internal error has occurred in the display. Example: Consult your Brodersen message display dealer for advice. 92-02-27 11:35:51 ALARM BOILER TEMPERATURE 98.6 C...
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 5.0 WIRING DIAGRAMS. 5.1 Inputs Signal from NPN Output Internal power supply of inputs General mode (code switch 3: Off). 0 1 2 3 4 5 6 7 8 C - +...
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 Signal from Potentialfree Contact 5.3 PC and Keyboard Programming Connector. Pin no. Keyboard PC 0 1 2 3 4 5 6 7 8 C - + Clock.
All manuals and user guides at all-guides.com Message Displays/Operator Panels Parallel Interface UCT-30/31/35 7.0 TECHNICAL DATA. VFD-type, 2 x 20 characters, 4 potential free push-buttons Display: Keypad: 5 x 7 dotmatrix with common terminal. Readable at a distance of up to Load: Max.
110-240 V AC supply voltage: Supply voltage: 250 mA T 12-48V AC/DC. 12-48 V AC/DC supply voltage: 110-240V AC. 800 mA T Mechanical dimensions: 1) UCT-30 is not available with printer output. 5 x 20 mm. Mains 40-60Hz frequency: ACCESSORIES Power External keyboard.
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 2. PROGRAMMIERUNG 2.2 Vor der Programmierung Die Textanzeige wird entweder mit einer Standard- Bevor die Versorgungsspannung an die XT-/AT-Tastatur oder mit einem IBM-kompatiblen Textanzeige gelegt wird, muß eine XT/AT-Tastatur PC programmiert.
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 2.3 Programmierung mit einer Tastatur 2.3.1 Setup Nach Anlegung der Betriebsspannung erscheint Die Setup-Parameter sind für alle Meldetexte der folgende Anzeige im Display: Textanzeige gemeinsam: - Anzeigeintensität TEXT DISPLAY UCT-XXX VERS.
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 Sonderzeichen sollten durch Festhalten der Taste 2.3.1.2 Zeichensatz <ALT> und gleichzeitige Eingabe der Sie können einen der folgenden Zeichensätze entsprechenden Zeichennummer auf der wählen: numerischen Tastatur eingegeben werden (nur Kompatibel mit AT-Tastatur).
BRODERSEN Mit den Tasten <TAB> oder <→ → → → → > wird der Cursor Alle Texte werden von Brodersen Control Systems vorwärts und mit <Backspace> oder <← ← ← ← ← > wird er A/S wie im obigen Beispiel programmiert.
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 2.3.3.1 Variablen 2.3.3.2 Uhrzeit/Datum (nur P-Version) Ein Meldetext kann bis zu 16 Variablen enthalten. Jahr, Monat, Tag, Stunde und Minuten können im Die variablen Ziffern können getrennt oder in Display angezeigt werden.
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 2.3.4 Speichern und Kopieren von Texten 2.3.4.1 Druckerausgabe (nur P-Version) Nachdem ein Text eingegeben/bearbeitet, z.B. Mit Hilfe dieser Funktion ist es möglich, Meldetexte Meldetext Nr. 078, und <CR>/<ENTER> gedrückt über einen externen Drucker auszudrucken.
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 2.4 Programmierung mit dem PC 2.4.1 PC-Editor UCP-201/202 Nachdem die Betriebsspannung angelegt worden Mit dem PC-Editor UCP-201/202 können Sie: ist, wird folgendes angezeigt: Meldetexte auf einem IBM-kompatiblen PC...
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 3.0 BETRIEB BCD-Code sein: Im Betrieb werden alle Daten zwischen der SPS Code/Address und der Textanzeige über die parallele 0 1 2 3 4 5 6 7 8 9 Schnittstelle übertragen.
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 Falls Sie nur eine geringe Anzahl von Meldetexten Eingang: Kommentar: benötigen, können die nicht benötigten Eingänge 8 7654 3210 Meldetext Nr. 005 wird gewählt. unbeschaltet bleiben. Wenn zum Beispiel die...
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 3.4 Idec-Izumi-Modus (nur UCT-31/31P/35/35P) 3.4.1 4-stellige Variablen (Schalter 2: OFF) Falls die Textanzeige durch eine Idec-Izumi-SPS Mit der Betriebsart „FUN 147-25“ der Idec-Izumi- gesteuert werden soll, kann dies wie in den SPS können Werte in 4 Variablen geladen werden.
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 3.4.2 16-stellige Variablen (Schalter 2: ON) Mit der Betriebsart „FUN 147-25“ können 16 0 DCBA 1110 Der Ziffernwert DCBA wird in variable Ziffern geladen werden. Da die Betriebsart Ziffernnummer 6 geladen.
Meldetexte aufnehmen. F¸r den Ausdruck gew‰hlte Meldetexte werden Betrieb & Programmierung: wie folgt ausgedruckt: In der Textanzeige ist ein interner Fehler aufgetreten. Beispiel: Setzen Sie sich mit Ihrem Brodersen-H‰ndler in Verbindung. 2-02-27 11:35:51 ALARM BOILER TEMPERATURE 98.6 C KEYBOARD ERROR...
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 5.0 BESCHALTUNG DER EINGÄNGE Signal von NPN-Ausgang 5.1 Eingänge Interne Stromversorgung für Eingänge. Normalbetrieb (Kodierschalter 3: OFF) 0 1 2 3 4 5 6 7 8 C - + UCT-Eingänge...
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 Signal von potentialfreiem Kontakt. 5.3 Anschluß (PC/Tastatur-Programmierung) 0 1 2 3 4 5 6 7 8 C - + Stift Tastatur Datum Sonstige Eingänge werden wie Eingang Nr. 0 angeschlossen.
All manuals and user guides at all-guides.com Textanzeigen Bedienkonsolen Parallele Schnittstelle UCT-30/31/35 7 TECHNISCHE DATEN Zeichensätze: Dänisch, Englisch, Deutsch, Schwedisch. Anzeige: VFD-Typ, 2x20 Zeichen, 5x7 Dänisch CP850, UK CP850, Punktmatrix Schwedisch CP850,Deutsch Ablesbar aus Entfernungen CP850, Schweizerisch/1 von bis zu 3 Metern.