Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INDHOLD
1
Generel beskrivelse ..................................... 3
2
Programmering ............................................. 4
2.1 Fremgangsmåde ..................................... 4
2.2 Før programmering ................................. 4
2.3 Programmering fra keyboard ................. 5
2.3.1 Opsætning ........................................... 5
2.3.1.1 Karaktersæt ...................................... 6
2.3.1.2 Display-lysniveau ............................. 7
2.3.1.3 Akustisk melding ............................... 7
2.3.2 Vælg en meddelelse ............................ 8
2.3.3.1 Variable cifre ..................................... 8
2.3.3.2 Tid/dato cifre ..................................... 9
2.3.4 Gem/kopier en meddelelse ................. 9
2.3.4.2 Akustisk Alarm ................................. 10
2.4 Programmering fra PC ........................... 11
2.4.1 PC-editor UCP-201/202 ...................... 11
3
Drift .............................................................. 12
3.2 Protokol ................................................. 12
3.2.1 Valg af meddelelse ............................. 12
3.2.2 Variable cifre ....................................... 12
3.2.3 Tid/dato cifre ....................................... 12
3.2.4 Taster .................................................. 13
3.3 Afbryd alarm .......................................... 14
4
5
System meddelelser .................................... 16
6
Stik ............................................................... 17
7
Kodeomskifter .............................................. 17
8
Tekniske data .............................................. 18
9
Tekstdisplay typer & tilbehør ....................... 19
10 PLC-drivere .................................................. 20
10.1 Idec FA2, FA2J, FA3 ........................... 20
10.2 ABB Procontic ...................................... 21
10.3 SIEMENS S5PLC ................................ 22
10.4 KOYO DL204, DL405 .......................... 23
10.5 IDEC MICRO 3 PLC ............................ 24
Brodersen Control Systems A/S • Betonvej 10 • DK-4000 Roskilde • Denmark • Tel (+45) 46 74 00 00 • Fax (+45) 46 75 73 36
Document 90251A Copyright © 1996 by Brodersen Control Systems A/S, Denmark.
Message Displays/Operator Panels
Serial Interface UCT-32/34
CONTENTS
U K
U K
U K
U K
U K
1 General Description ........................................ 3
2 Programming ................................................ 25
2.1 ProgrammingStrategy ............................. 25
2.2 Before Programming ............................... 25
2.3 Programming from Keyboard .................. 26
2.3.1 Set-up .................................................. 26
2.3.1.1 Character Set ................................... 27
2.3.1.2 Display-intensity ............................... 28
2.3.1.3 Acoustic Alert .................................... 28
2.3.2 Select a Message ................................ 29
2.3.3 Create/Edit a Message ....................... 29
2.3.3.1 Variable Digits ................................... 29
2.3.3.2 Time/dateDigits ................................. 29
2.3.4 Save/Copy a Message ........................ 30
2.3.4.2 Acoustic Alarm .................................. 31
2.4 Programming from PC ............................ 32
2.4.1 PC Editor UCP-201/202 ....................... 32
3
Operation ...................................................... 33
3.2 Protocol ................................................. 33
3.2.1 Message Selection .............................. 33
3.2.2 Variable Digits ...................................... 33
3.2.3 Time/date Digits ................................... 33
3.2.4 Keypad ................................................ 34
3.2.5 Numerical Entry ................................... 34
3.3 Alarm Acknowledgement ....................... 35
4
Editing Set-up from the Keypad .................... 36
5
System Messages ........................................ 37
6
Connectors ................................................... 38
7
CodeSwitch .................................................. 38
8
Technical Data ............................................. 39
9
10 PLC drivers .................................................. 41
10.1 Idec FA2, FA2J, FA3 ............................ 41
10.2 ABB Procontic ...................................... 42
10.3 SIEMENS S5PLC ................................. 43
10.4 KOYO DL204, DL405 ........................... 44
10.5 IDEC MICRO 3 PLC ............................ 45
11 Numerical Entry Samples ............................. 67
UCT-32/34
1

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Brodersen UCT-32

  • Seite 1: Inhaltsverzeichnis

    11 Numerical Entry Samples ......67 Brodersen Control Systems A/S • Betonvej 10 • DK-4000 Roskilde • Denmark • Tel (+45) 46 74 00 00 • Fax (+45) 46 75 73 36 Document 90251A Copyright © 1996 by Brodersen Control Systems A/S, Denmark.
  • Seite 2 10.2 ABB Procontic ........63 10.3 SIEMENS S5PLC ........ 64 10.4 KOYO DL205, DL405 ......65 10.5 IDEC MICRO 3 PLC ......66 11 Beispiele mit numerischen Tasten ....67 Document 90251A Copyright © 1996 by Brodersen Control Systems A/S, Denmark.
  • Seite 3: Generel Beskrivelse

    3xP version has a parallel printer output and battery backed-up real-time clock which enables printing of production data, events, alarms etc. Brodersen Control Systems A/S • Betonvej 10 • DK-4000 Roskilde • Denmark • Tel (+45) 46 74 00 00 • Fax (+45) 46 75 73 36...
  • Seite 4: Programmering

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 2 PROGRAMMERING. 2.2 Før programmering. Tekstdisplayet programmeres enten fra et stan- Før du tilslutter forsyningsspænding til tekstdis- dard XT-/AT-keyboard eller fra en IBM kompatibel playet, skal der tilsluttes et XT-/AT-keyboard eller en PC. 2.1 Fremgangsmåde. Indstil kodeomskifteren:...
  • Seite 5: Programmering Fra Keyboard

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 2.3 Programmering fra keyboard. 2.3.1 Opsætning. Når forsyningsspændingen er tilsluttet, viser tekst- Opstætningsparametrene er fælles parametre for displayet: alle meddelelser i tekstdisplayet: TEXT DISPLAY - Karaktersæt (nationalt). UCT-XXX VERS. Y.YY - Display-intensitet. xxx : Tekstdisplay type.
  • Seite 6: Karaktersæt

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 2.3.1.1. Karaktersæt. Der kan vælges et af følgende karaktersæt: tasten nede og indtaste den tilhørende kode på det numeriske tastatur (kun AT-keyboard). Karaktersættene 5-10 (CP850) supporteres ikke Dansk Kompatibel med tidlige- af XT-key boards. re UCT-20/30/40 ver si- Engelsk oner.
  • Seite 7: Display-Lysniveau

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 2.3.1.2 Display intensitet. Display-intensitet kan programmeres i 4 niveauer: Vælg akustisk signal ved at taste 1, eller koble 20%, 40%, 60% eller 100% (default). signalet fra ved at taste 0. Dette gælder for tasta- turet (KEY) eller meddelelserne (TXT).
  • Seite 8: Vælg En Meddelelse

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 2.3.2 Valg af meddelelse. 2.3.3.1 Variable cifre. Vælg en meddelelse ved at indtaste det aktuelle Op til 16 variable kan indeholdes i én meddelelse. nummer, f.eks. 078. Meddelelserne er nummere- De variable cifre kan frit placeres i meddelelsen, rede 000-189, og alle tre cifre skal indtastes.
  • Seite 9: Tid/Dato Cifre

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 2.3.3.2 Tid/Dato cifre (kun P-version). 2.3.4 Gem/kopier en meddelelse. År, måned, dato, timer og minutter kan udlæses Når en meddelelse er indtastet/redigeret, f.eks. på displayet i enhver position i en meddelelse. meddelelse nr. 078, og der er trykket Tid og dato afledes fra det indbyggede ur.
  • Seite 10: Akustisk Alarm

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 2.3.4.2 Akustisk alarm. Til en meddelelse kan der vælges en akustisk alarm med en karakteristisk lyd, til en meddelelse. Under drift begynder alarmen med: BIP-BIP-BIP- ... når meddelelsen er valgt, og alarmen fortsætter, indtil operatøren nulstiller den ved at trykke en af tasterne på...
  • Seite 11: Programmering Fra Pc

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 2.4. Programmering fra PC. 2.4.1 PC-editor UCP-201/202. PC-editoren UCP-201/202 giver mulighed for at: Når forsyningsspændingen er tilsluttet, viser tekst- displayet: Indtaste og redigere meddelelser på en IBM- kompatibel PC TEXT DISPLAY Gemme meddelelser på diskette eller hard- UCT-XXX VERS.
  • Seite 12: Drift

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 3 DRIFT. 3.2 Interface/Protokol. I drift overføres alle data mellem PLC og tekstdis- Detaljerede specifikationer om kodeomskifterind- playet via seriel interface. Valg af meddelelse, va- stillinger og dataregistre i de PLC'er, tekstdis- riable cifre, tid/dato data og tastaturinformation playet supporterer, er vist i afsnit 10.
  • Seite 13: Taster

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 3.2.4 Tastatur. Så længe der trykkes på en tast, overføres der Eksempel på taste sekvens. data til PLC'en. Taster, som ikke er installeret eller benyttet bliver sat til 0. Tekstdisplayet kan overføre informationer fra op til to taster på samme tid.
  • Seite 14: Afbryd Alarm

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 3.3 Alarm nulstilling. Eksempel: Når en meddelelse med tildelt akustisk alarm er valgt, biper alarmen, indtil den bliver nulstillet: BIP-BIP-BIP-..92-02-27 11:35:51 En alarm nulstilles ved at trykke en vilkårlig taste ALARM BOILER på tastaturet. Hermed ophører alarmen, og tasta- TEMPERATURE 98.6 C...
  • Seite 15: Acoustic Feedback

    ACOUSTIC FEEDBACK tastatur. KEY=1 TEXT=1 Brug tasten, <P> (UCT-32) eller <C> (UCT-34), Fjern forsyningsspændingen, og indstil kodeom- for at flytte cursoren mellem (KEY) og (TEXT) skifteren: vælger. Brug tasterne, <! ! ! ! ! >/<" " " " " >, for at switche opsætnin- Code/Address gen On eller Off.
  • Seite 16: System Meddelelser

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 5 SYSTEM MEDDELELSER. Dette er en liste af UCT-systemmeddelelser, der PLC SELECT ERROR kan forekomme i tekstdisplayet. ILLEGAL TEXT NO. Dil switch 5, 6 eller 7 står i forkert position. Drift & programmering: Et ugyldigt nummer er specificeret, når en meddelelse vælges eller gemmes.
  • Seite 17: Stik

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 6 STIK. 7 KODEOMSKIFTER Code/Address Stik til PC og keyboardprogrammering. 0 1 2 3 4 5 6 7 8 9 Pin no. Keyboard PC Clock. Data fig. 9 Indstillingerne af kodeomskifteren bliver loaded når tekstdisplayet tilsluttes forsynings- spændingen.
  • Seite 18: Tekniske Data

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 8 TEKNISKE DATA. Serial input: RS232C (standard version). Display: VFD-type, 2 x 20 karakterer, 5 x 7 punktmatrix. Option A, K: RS232C. Option I: Der er ikke tilpasset standard- Læsbar op til 3 meter afstand. Displayfelt: 125 x 22 mm.
  • Seite 19: Tekstdisplay Typer & Tilbehør

    UCT-34 Isolation: Forsyning: IEC klasse II, 4kV AC. Printerudgang: Ingen Dimensioner: Printerudgang Front: UCT-32: 192 x 48 mm. I henhold til DIN43700. Forsyning: UCT-34: 192 x 96 mm. 12-48V AC/DC. I henhold til DIN43700. 110-240V AC. Dybte: 96 mm + konnektorer (10 mm) Optioner: + front (9 mm).
  • Seite 20: Plc-Drivere

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 10.1 Idec FA2, FA2J, FA3. Tid/dato cifre UCT # PLC Retning Kodeomskifter indstillinger. Data Område Bank A Bank B Code/Address Sekunder 0-59 DR890 DR1790 0 1 2 3 4 5 6 7 8 9 Minutter 0-59...
  • Seite 21: Abb Procontic

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 10.2 ABB Procontic. Tid/dato cifre UCT # PLC CPU type: 07KR31, 07KR91, 07KT92, 07KP62 & Retning 35ZE94 (active mode). Data Område Bank A Bank B Sekunder 0-59 MW250.08 MW239.08 Minutter 0-59 MW250.09 MW239.09 Tilslutninger til tekstdisplay.
  • Seite 22: Siemens S5Plc

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 10.3 SIEMENS S5PLC. CPU type: S5/95U, S5/100U, S5 115U/CPU941 & RECEIVE_MAIL_BOX CPU/942. UCT # PLC Retning Byte Beskrivelse Type Område Forbindelser til tekstdisplay. LÆNGDE binært =14 Standardkabel: UCC-217. SOURCE binært =0 Pin 2: TTY in + Skudår...
  • Seite 23: Koyo Dl204, Dl405

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 10.4 KOYO DL205, DL405. Time/date digits UCT # PLC CPU type: DL230, DL240, DL430, DL440. Retning Data Område Reference Kodeomskifter-indstilling. Sekunder 0-59 V2366 Minutter 0-59 V2367 Code/Address Timer 0-23 V2370 0 1 2 3 4 5 6 7 8 9...
  • Seite 24: Idec Micro 3 Plc

    Tekstdisplays/Operatørpaneler Serielt interface UCT-32/34 10.5 IDEC MICRO 3 PLC Tastatur UCT # PLC Retning Forbindelser til tekstdisplay. Data Reference Bit nr. Standardkabel: UCC-219 (ikke brugt) Signalniveau: RS485. Rgnd RTS Data Gnd Pin 5: Data - (brun) Pin 4: Data + (hvid) é...
  • Seite 25: Programming

    Message Displays/Operator Panels Serial Interface UCT-32/34 2 PROGRAMMING. 2.2 Before Programming. The message display is programmed from a stand- Before you connect the supply voltage to the ard XT/AT keyboard or from an IBM compatible message display, connect the message display to a XT/AT keyboard or to PC.
  • Seite 26: Programming From Keyboard

    Message Displays/Operator Panels Serial Interface UCT-32/34 2.3 Programming from Keyboard. 2.3.1 Set-up. When supply voltage is connected, the message The set-up parameters are common parameters display shows: for all messages of the message display: TEXT DISPLAY - Character set (nationality).
  • Seite 27: Character Set

    Message Displays/Operator Panels Serial Interface UCT-32/34 2.3.1.1. Character Set. The message display has 10 character sets to Special characters should be entered by holding select from: down the <ALT> key while entering the corre- sponding character number using the numerical keyboard.
  • Seite 28: Display-Intensity

    Message Displays/Operator Panels Serial Interface UCT-32/34 2.3.1.2 Display-intensity. Display-intensity is programmable in 4 levels: Select acoustic feedback by entering 1, or disable 20%, 40%, 60% or 100% (default). by entering 0, at the required selector (KEY)/ (TEXT). Press <CR>/<ENTER> to save setting and exit The display-intensity menu is selected by typing the menu.
  • Seite 29: Select A Message

    Message Displays/Operator Panels Serial Interface UCT-32/34 2.3.2 Select a Message. 2.3.3.1 Variable Digits. Select a message by entering the actual number Up to 16 variable digits can be contained in a e.g. 078. The messages are numbered 000-189 message. The variable digits can be placed at any and all 3 digits must be entered.
  • Seite 30: Save/Copy A Message

    Message Displays/Operator Panels Serial Interface UCT-32/34 2.3.3.2 Time/Date Digits (P-version only). 2.3.4 Save/Copy a Message. Year, month, date, hour and minutes can be After having created/edited a message e.g. mes- displayed at any position in each message. sage no. 078 and having pressed <CR>/<EN- The time and date are derived from built-in real- TER>, the display shows:...
  • Seite 31: Acoustic Alarm

    Message Displays/Operator Panels Serial Interface UCT-32/34 2.3.4.2 Acoustic Alarm. An acoustic alarm with a characteristic sound can be assigned to a message. In operation, the acoustic alarm will start sound- ing: BEEP-BEEP-BEEP-..when the message is selected and will continue to sound until the operator has acknowledged the alarm by press- ing any of the keys at the keypad.
  • Seite 32: Programming From Pc

    Message Displays/Operator Panels Serial Interface UCT-32/34 2.4. Programming from PC. 2.4.1 PC Editor UCP-201/202. When supply voltage is connected the message The PC editor UCP-201/202 lets you: display shows: Create and edit messages on an IBM com- patible PC. TEXT DISPLAY Save messages on floppy disk or hard disk.
  • Seite 33: Operation

    Message Displays/Operator Panels Serial Interface UCT-32/34 3 OPERATION. 3.2 Interface/Protocol. In operation all data are transferred between the Detailed specifications on code switch settings PLC and the message display via the serial inter- and data registers for all PLCs supported is listed face.
  • Seite 34: Keypad

    Message Displays/Operator Panels Serial Interface UCT-32/34 3.2.4 Keypad. The key data is transmitted to the PLC as long as Example of key sequence a key is pressed. Keys not installed/used are set to zero. The message display transmits information of up...
  • Seite 35: Alarm Acknowledgement

    Message Displays/Operator Panels Serial Interface UCT-32/34 3.3 Alarm Acknowledgement. When a message is selected and acoustic alarm Example: has been assigned to the message, the acoustic alarm continues to sound until the alarm is ac- 92-02-27 11:35:51 knowledged: ALARM BOILER BEEP-BEEP-BEEP-..
  • Seite 36: Editing Set-Up From The Keypad

    KEY=1 TEXT=1 the message display via the keypad. Use the <P> (UCT-32) or <C> (UCT-34) key to Enter front set-up by disconnecting supply vol- move the cursor between the (KEY) and (TEXT) tage and setting the code switch: selector.
  • Seite 37: System Messages

    Check and correct connections. TEXT DISPLAY ERROR Operation & Programming mode: An internal error has occurred in the text display. Consult your Brodersen message display dealer for advice. ILLEGAL TIME/DATE Programming mode: An invalid value has been entered during real-time clock adjustment.
  • Seite 38: Connectors

    Message Displays/Operator Panels Serial Interface UCT-32/34 6 CONNECTORS. 7 CODE SWITCH. Code/Address PC and Keyboard Programming Connector. 0 1 2 3 4 5 6 7 8 9 Pin no. Keyboard PC Clock. Data fig. 9 The setting of the code switch is loaded when the message display is connected to supply voltage.
  • Seite 39: Technical Data

    Message Displays/Operator Panels Serial Interface UCT-32/34 8 TECHNICAL DATA. Serial input: RS232C (general version). Display: VFD-type, 2 x 20 characters, Option A, K: RS232C. 5 x 7 dotmatrix. Readable at a distance of up to Option I: Non standard levels adapted to the programming port of the 3 m.
  • Seite 40: Mechanical Dimensions

    UCT-34 Isolation: Mains: IEC class II, 4kV AC. Printer output: No printer Dimensions: Printeroutput Front: UCT-32: 192 x 48 mm according to Supply voltage: DIN43700. 12-48V AC/DC. UCT-34: 192 x 96 mm according to 110-240V AC. DIN43700. Depth: 96 mm + connectors (10 mm) + Options: front (9 mm).
  • Seite 41: Plc Drivers

    Message Displays/Operator Panels Serial Interface UCT-32/34 10.1 Idec FA2, FA2J, FA3. Time/date digits UCT # PLC Direction Code Switch Setting. Data Range Bank A Bank B Seconds 0-59 DR890 DR1790 Code/Address 0 1 2 3 4 5 6 7 8 9...
  • Seite 42: Abb Procontic

    Message Displays/Operator Panels Serial Interface UCT-32/34 10.2 ABB Procontic. Time/date digits CPU type: 07KR31, 07KR91, 07KT92, 07KP62 & UCT # PLC Direction 35ZE94 (active mode). Data Range Bank A Bank B Seconds 0-59 MW250.08 MW239.08 Minutes 0-59 MW250.09 MW239.09 Connections to Message Display.
  • Seite 43: Siemens S5Plc

    Message Displays/Operator Panels Serial Interface UCT-32/34 10.3 SIEMENS S5PLC. CPU type: S5/95U, S5/100U, S5 115U/CPU941 & RECEIVE_MAIL_BOX CPU/942. UCT # PLC Direction Byte Description Type Range Connections to Message Display. LENGHT binary =14 Available cable: UCC-217. SOURCE binary =0 Pin 2: TTY in +...
  • Seite 44: Koyo Dl204, Dl405

    Message Displays/Operator Panels Serial Interface UCT-32/34 10.4 KOYO DL205, DL405. Time/date digits UCT # PLC CPU type: DL230, DL240, DL430, DL440. Direction Data Range Reference Code Switch Setting. Seconds 0-59 V2366 Minutes 0-59 V2367 Code/Address Hours 0-23 V2370 0 1 2 3 4 5 6 7 8 9...
  • Seite 45: Idec Micro 3 Plc

    Message Displays/Operator Panels Serial Interface UCT-32/34 10.5 IDEC MICRO 3 PLC Keypad UCT # PLC Direction Connections to Message Display. Data Reference Bit no. Available cable: UCC-219 (not used) Signal level: RS485. Rgnd RTS Data Gnd Pin 5: Data - (brun) Pin 4: Data + (hvid) &...
  • Seite 46: Programmierung

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 2. PROGRAMMIERUNG 2.2 Vor der Programmierung Die Textanzeige wird entweder mit einer Standard- Bevor die Versorgungsspannung an die XT-/AT-Tastatur oder einem IBM-kompatiblen PC Textanzeige gelegt wird, muß eine XT/AT-Tastatur programmiert. oder ein PC an die Textanzeige angeschlossen werden.
  • Seite 47: Programmierung Mit Einer Tastatur

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 2.3 Programmierung mit einer Tastatur 2.3.1 Konfiguration Nach dem Angelegen der Betriebsspannung Die Konfigurationsparameter gelten für alle erscheint folgende Meldung in der Textanzeige: Meldetexte der Textanzeige gemeinsam: Zeichensatz (national) TEXT DISPLAY UCT-XXX VERS. Y.YY Anzeigeintensität...
  • Seite 48: Zeichensatz

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 2.3.1.1 Zeichensatz Für die Textanzeige können Sie einen der Sonderzeichen sollten durch Festhalten der Taste folgenden 10 Zeichensätze wählen: <ALT> gleichzeitige Eingabe entsprechenden Zeichennummer auf der Kompatibel mit alten 1. Dänisch numerischen Tastatur eingegeben werden. Die UCT-20/30/40- Versionen.
  • Seite 49: Anzeigeintensität

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 2.3.1.2 Anzeigeintensität Durch Eingabe von 1 können Sie die akustische Die Intensität der Anzeige ist vierstufig einstellbar: 20%, 40%, 60% oder 100% (Standard). Meldung wählen und durch Eingabe von 0 können Sie diese abschalten. Dies gilt für die Wählen Sie das Menü...
  • Seite 50: Wählen Von Texten

    Plazieren Sie den Cursor an die Stelle, an der BRODERSEN eine variable Ziffer erscheinen soll. Alle Texte werden von Brodersen Control Systems Halten Sie die Taste <ESC> gedrückt und geben A/S als Grundeinstellung wie im obigen Beispiel Sie eine Ziffer ein: programmiert.
  • Seite 51: Uhrzeit/Datum (Nur P-Version)

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 2.3.3.2 Uhrzeit/Datum (nur P-Version) 2.3.4 Speichern und Kopieren von Texten Jahr, Monat, Tag, Stunde und Minuten können im Nachdem ein Text eingegeben/bearbeitet, z.B. Meldetext beliebig angezeigt werden. Meldetext Nr. 078, und <CR>/<ENTER> gedrückt Die Uhrzeit und das Datum werden von der worden ist, erscheint folgende Anzeige: eingebauten Echtzeituhr abgeleitet.
  • Seite 52: Akustischer Alarm

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 2.3.4.2 Akustischer Alarm Jedem Meldetext (Alarm) kann ein akustisches Signal zugeordnet werden. Im Betrieb wird der akustische Alar m als Intervallton angegeben, sobald ein Text gewählt wird, bis der Anwender den Alarm durch Drücken einer der Tasten der Fronttastatur quittiert hat.
  • Seite 53: Speichern Und Kopieren Von Texten

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 2.4 Programmierung mit dem PC 2.4.1 PC-Editor UCP-201/202 Nachdem die Betriebsspannung angelegt worden Mit dem PC-Editor UCP-201/202 können Sie: ist, wird folgendes angezeigt: - Meldetexte auf einem IBM-kompatiblen PC eingeben und bearbeiten, TEXT DISPLAY - Meldetexte auf Diskette oder Festplatte UCT-XXX VERS.
  • Seite 54: Betrieb

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 3 BETRIEB 3.2 Schnittstelle/Protokoll Im Betrieb erfolgt die Übertragung aller Daten Detaillierte Spezifikationen der Schaltereinstel- zwischen der SPS und der Textanzeige über die lungen und Datenregister für alle SPS-Steuer- serielle Schnittstelle. ungen, die unterstützt werden, sind in Abschnitt Die Wahl von Meldetexten, Variablen, 10 aufgelistet.
  • Seite 55: Fronttastatur

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 3.2.4 Fronttastatur Die Tastendaten werden solange zur SPS Beispiel für Tastenfolgen übertragen, bis keine Tasten mehr betätigt werden. Tasten, die nicht installier t bzw. verwendet werden, werden auf Null gesetzt. Taste Wert Bemerkung Die Textanzeige überträgt Informationen von bis Löscht die letzte Eingabe.
  • Seite 56: Alarmbestätigung (Hupenquittierung)

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 3.3 Alarmbestätigung Beispiel: Nachdem ein Meldetext gewählt und ihm ein akustischer Alarm zugeordnet worden ist, ertönt der akustische Alarm, bis er quittiert wird: Intervallton..92-02-27 11:35:51 ALARM BOILER Ein Alarm läßt sich durch Betätigung einer TEMPERATURE 98.6 C...
  • Seite 57: Bearbeiten Des Setup Mit Der Front- Tastatur

    Textanzeige mit der Fronttastatur bearbeitet KEY=1 TEXT=1 werden. Schalten Sie das Gerät aus und stellen Sie den Benutzen Sie die <P>-Taste (UCT-32) oder <C>- Kodierschalter ein: Taste (UCT-34), um den Cursor zwischen dem (KEY)- und (TEXT)-Wähler zu bewegen. Code/Address 0 1 2 3 4 5 6 7 8 9 Betätigen Sie die <↑...
  • Seite 58: Systemmeldungen

    Prüfen und stellen Sie die Verbindungen her. TEXT DISPLAY ERROR Betrieb & Programmierung: In der Textanzeige ist ein interner Fehler aufgetreten. Setzen Sie sich mit Ihrem Brodersen-Händler in Verbindung. ILLEGAL TIME/DATE Programmierung: Ein ungültiger Wert wurde beim Stellen der Echtzeituhr eingegeben.
  • Seite 59: Beschaltung

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 BESCHALTUNG KODIERSCHALTER Stecker für das Programmieren mit dem PC und Code/Address der Tastatur 0 1 2 3 4 5 6 7 8 9 Stift Nr. Tastatur Clock Daten Abb. 9 Die Einstellung des Kodierschalters wird bei Anlegung der Versorgungsspannung geladen.
  • Seite 60: Technische Daten

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 8 TECHNISCHE DATEN Schwedisch CP850, Deutsch CP850, Schweizerisch/1 Anzeigentyp: VFD-Typ, 2x20 Zeichen, CP850, Französisch CP850. 5x7 Punktmatrix Besondere Zeichensätze auf Ablesbar aus Entfernungen Anfrage. von bis zu 3 Metern. Anzeigefeld: 125x22mm Serieller Eingang: RS232C(allgemeinVersion). Höhe der Option A, K: RS232C.
  • Seite 61: Mechanische Abmessungen

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 Frequenz: 40-60 Hz. ANZEIGETYPEN & ZUBEHÖR Leistungs- Anzeigentyp: UCT-32 P 230 aufnahme: Etwa 10W. Umgebungs- Anzahl der Tasten: temperatur: -20 bis +50°C. UCT-32 UCT-34 Schutzart: Frontseitig: IP65 Rückseitig: IP20 Druckeranschluß: Keiner: EMC: Gemäß EN50081-1, Druckeranschluß...
  • Seite 62: Sps-Treiber

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 10.1 Idec FA2, FA2J, FA3 Ziffern für Uhrzeit/Datum UCT # SPS Richtung Daten Bereich Bank A Bank B Code/Address Sekunden 0-59 DR890 DR1790 0 1 2 3 4 5 6 7 8 9 Minuten 0-59...
  • Seite 63: Abb Procontic

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 10.2 ABB Procontic Ziffern für Uhrzeit/Datum UCT # SPS CPU-Typ: 07KR31, 07KR91, 07KT92, 07KP62 und Richtung 35ZE94 (aktive Betriebsart). Daten Bereich Bank A Bank B Sekunden 0-59 MW250.08 MW239.08 Anschlüsse an Textanzeige Minuten 0-59 MW250.09 MW239.09 Verfügbares Kabel: UCC-216.
  • Seite 64: Siemens S5Plc

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 10.3 SIEMENS S5PLC CPU-Typ: S5/95U, S5/100U, S5 115U/CPU941 RECEIVE_MAIL_BOX und CPU/942 Richtung UCT # PLC Byte Beschreibung Bereich Anschlüsse an Textanzeige LÄNGE Binär = 14 Verfügbares Kabel: UCC-217 SOURCE Binär Pin 2: TTY in +...
  • Seite 65: Koyo Dl205, Dl405

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 10.4 KOYO DL205, DL405. Ziffern für Uhrzeit/Datum UCT # SPS CPU Typ: DL230, DL240, DL430, DL440. Richtung Daten Bereich Referenz Kodierschalter-Einstellung Sekunden 0-59 V2366 Minuten 0-59 V2367 Code/Address Stunden 0-23 V2370 0 1 2 3 4 5 6 7 8 9...
  • Seite 66: Idec Micro 3 Plc

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 10.5 IDEC MICRO 3 PLC Kleintastatur UCT # SPS Richtung Anschlüsse an Textanzeige Daten Referenz Bit Nr. Verfügbares Kabel: UCC-216. -(nicht benutzt) DR5 Signalpegel: RS485. Rgnd RTS Data Gnd Pin 5: Data - (brun) Pin 4: Data + (hvid) &...
  • Seite 67: Eksempler Med Numeriske Taster

    Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 Eksempel 1 / Example 1 / Beispiel 1 Operatørpanel Operator panel Terminals Application Text no. programme Var. # 1 Var. # 2 SP: 2000 PV: 1099 Var. # 3 Numeric entry Var. # 4 5678...
  • Seite 68 Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 Eksempel 2 / Example 2 / Beispiel 2 Operatørpanel Operator panel Terminals Application Text no. programme Var. # 1 Process parameter Var. # 2 entry 3333 Var. # 3 Var. # 4 F1 F2 F3...
  • Seite 69 Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 Eksempel 3 / Example 3 / Beispiel 3 Operatørpanel Operator panel Terminals Application Text no. programme Var. # 1 Var. # 2 Parameter Var. # 3 Entry 9999 Var. # 4 Counter Keys Num entry Registers Piltasterne, <! ! ! ! ! >/<"...
  • Seite 70 Textanzeigen Terminals Serielle Schnittstelle UCT-32/34 6 STIK/CONNECTORS/BESCHALTUNG 7 KODEOMSKIFTER CODE SWITCH. Stik til PC og keyboardprogrammering. KODIERSCHALTER. PC and Keyboard Programming Connector. Stecker für das Programmieren mit dem PC und Code/Address der Tastatur. 0 1 2 3 4 5 6 7 8 9 Pin no.

Diese Anleitung auch für:

Uct-34

Inhaltsverzeichnis