Herunterladen Inhalt Inhalt Diese Seite drucken

LEMANIA ENERGY LE25.0 Bedienungsanleitung Seite 8

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24
6. Pulse Rescue Dead Battery
At the start of the charging program the charger detects the battery voltage and
automatically starts the pulse charging program if the voltage is between 4.5V±0.29V to
10.5V±0.29V (12V battery) or 15V±0.5V to 21V±0.42V (24V battery).This process will continue
until the battery voltage reaches 10.5V±0.29V (12V battery) or 21V±0.42V (24V battery), once
the battery reaches these levels the charger will continue according to the selected
program.
7. Abnormality Protection
The charger will automatically protect itself if it detects abnormal conditions such as,
short circuit, 12V battery voltage below 4.5±0.5V, 24V battery voltage below 15V±0.25V,
open circuit or reverse polarity connection. When any of these conditions are detected
the charger will return to standby mode . In addition to this will illuminate if the
connections to the battery are reversed.
9. Changing between modes.
To change mode, press the MODE button until the desired. Once the mode button is
pressed, after 0.5 seconds the charger will change its mode.
a. 12V batteries are compatible with the following modes: Standby, Mode 2, Mode 2.1, Mode
3 and Mode 4. The charger will cycle in this order. Please note that to access model 3 the
charger must be powered, not connected to the battery and the mode button must be
pressed for 3 seconds. Once this is complete the charger can be connected to the battery,
ensuring that the connections are correct as polarity protection is disabled.
b. 24V batteries are compatible with the following modes: Standby, Mode1. Mode 1.1. The
Charger will cycle in this order.
If a battery is not disconnected from the charger once fully charged, the charger will
remain in the trickle charging mode even if the user attempts to change the mode
manually. This protects fully charged batteries from damage.
10. Charging status indication
LED 25%
Flashing
ON
ON
ON
ON
11. Memory function
This Smart Battery charger has a unique memory function (not applicable to the 13.6V
Supply and 16V boost mode). The charger returns to last selected mode automatically
when power is switched on after a cut in AC power.
07
LED 50%
LED 75%
OFF
OFF
Flashing
OFF
ON
Flashing
ON
ON
ON
ON
MODES
LED 100%
OFF
OFF
OFF
Flashing
ON
Charging Status
Under 25%
Under 50%
Under 75%
Under 100%
Fully Charged