All operating elements and connections described
can be found on the fold-out page 3.

1 Operating Elements and Connections

1.1 Receiver
1 POWER LED
2 Reception LED RF
3 Overload indicator PEAK (independent of the vol-
ume control)
4 Control VOLUME with On/Off switch (on the right
side of the device)
5 Output AUDIO OUT (6.3 mm jack, unbal.) for con-
necting to a microphone input
6 Connection DC IN for a power supply unit (included
in the delivery)
7 Control SQUELCH for adjusting the muting thresh old
(at the bottom of the device)
8 Antenna
1.3 Microphone with integrated transmitter
9 Screw cap
10 Battery compartment for a 9 V battery
11 Power switch
lower position:
medium position: Mute
upper position:
12 Power LED

2 Safety Notes

The units (microphone, receiver, plug-in power supply
unit) correspond to all required directives of the EU and
are therefore marked with
WARNING
The plug-in power supply unit is supplied
with hazard ous mains voltage (230 V~).
Leave servic ing to skilled personnel only.
Inexpert handling may cause an electric
shock hazard.
For operation also observe in any case the following:
G
The units are suitable for indoor use only. Protect
them against dripping water and splash water, high
air humidity, and heat (ambient temperature range
0 – 40 °C).
G
Even if the receiver is switched off, the plug-in power
supply has a low power consumption.
G
Do not set the receiver to operation and immediately
disconnect the plug-in power supply from the mains if:
1. damage at the plug-in power supply or the receiver
is visible,
2. a defect might have occurred after a drop or similar
accident,
3. there are malfunctions.
The units must be repaired in any case by author ized
personnel.
G
For cleaning only use a dry, soft cloth, by no means
chemicals or water.
G
No guarantee claims for the units and no liability for
any resulting personal damage or material damage
6
Off
On
.
will be accepted if the units are used for other pur-
poses than originally intended, if they are not correctly
connected, operated, or not repaired in an expert way.
If the units are to be put out of operation defini-
tively, take them to a local recycling plant for a
disposal which is not harmful to the environ-
ment.
3 Applications
The wireless microphone system consists of a micro-
phone with integrated, battery-operated transmitter and
antenna, the corresponding receiver as well as a plug-in
power supply. This system allows wireless music and
speech transmission from the microphone to the re -
ceiver. The operating range is approx. 30 m and
depends on local conditions.
The microphone system is available for three differ -
ent transmission channels (transmission frequencies):
Model
Frequency
TXS-100SET
175.00 MHz
TXS-102SET
195.25 MHz
TXS-103SET
197.10 MHz
Thus, signals of three microphones can be transmitted
on different channels when using three models. Due to
the colour code it can easily be recognized which micro-
phone cooperates with the respective receiver.
3.1 Conformity and Approval
Herewith, MONACOR INTERNATIONAL de clare that
the units TXS-100SET, TXS-102SET and TXS-103SET
are in accordance with the basic requirements and the
other relevant regulations of the directive 1999/5/EC.
The declaration of conformity can be found in the
Internet via the MONACOR INTER NATIONAL home
page (www.imgstageline.com).
In the Federal Republic of Germany, a frequency
assignment (for which a charge is payable) is re quired
for the wireless transmitters. The forms and notes con-
cerning the registration for the transmitters can be found
in the Internet on the Web site of the Bun desnetzagentur
(Federal Network Agency) under:
www.bundesnetzagentur.de.
In other countries, it is necessary to apply for a corre-
sponding approval. Prior to operating the system outside
Germany, please contact the MONACOR subsidiary or
the correspond ing authorities of the respective country.

4 Power Supply

4.1 Microphone
1) Screw off the screw cap (9) at the lower end of the
microphone.
2) Insert a 9 V battery with the positive and negative
connections as printed in the battery compartment
(10). Tightly screw the screw cap (9) again.
3) With a new battery the microphone can be oper ated
for approx. 6 – 8 hours.
4) If not used for a longer period of time (e. g. for more
than one week), the battery should be taken out of