The connections to be made by the installer are as follows:
- Electrical supply line
- Thermostat line
- Warning light (optional)
- Timer (optional)
- Flame control thermostat (optional)
Eliminate any cable bridges
N.B.: It is necessary to observe scrupulously normal working practices that indicate attachment of no more than two
cables per terminal.
Warning:
- Do not exchange the neutral with the phase
- Be sure to make a good connection for the ground wire
- Respect normal working practices and observe scrupulously local regulations in force
LIGHT OIL SUPPLY
The dimensions of the fuel lines (diameter/length) are related to the type of burner (with one or two lines, in suction feed /
gravity feed) and with the pump specifications.
The diagram indicates the maximum length L allowed in a suction feed line with regards to the difference in height of the
fuel tank and the internal diameter of the tube d, for an atmospheric pressure of 1013 mbar and a vacuum of 0.45 bar,
considering assembly with 4 elbows of a stop valve and a one-way valve.
SINGLE LINE FUEL SUPPLY
It is recommended whenever possible to avoid this option, which can create significant malfunctions in the burner if the
installation has not been performed in a perfect manner. However, if it is not possible to avoid this choice, we advise: use
a gravity feed burner only, modify the pump by removing the Allen-head screw inside, discharge air from the upper parts
of the fuel line and avoid air bubbles.
DOUBLE LINE FUEL SUPPLY