Accuracy Check
Vertical plumb points
Checking the accuracy of the upper plumb
point:
Place the lock switch in the "Unlocked" position
(see
Levelling
lock). Set up the laser on its tripod to
wall mount bracket near point A1 at a minimum dis-
tance of 1.5 m from point B1. The horizontal laser
is aligned in direction 1. Mark the laser points A1
and B1 with a pin.
Makita SK106D/SK106GD
Checking the accuracy of the lower plumb
point:
Rotate the instrument by 180° so that it points in
the opposite direction 2 to direction 1. Adjust the
instrument so that the laser beam hits point A1
exactly. If point B2 is no further than 2 mm away
from point B1, then the instrument is within tol-
erance.
Should your instrument be outside of the spe-
cified tolerance, please contact a local dealer
or an authorised Makita distributor.