MOUNTING
Disconnect power supply by the phase fuse, the circuit-breaker or the switch-
disconnector combined to the proper circuit.
Check if there is no voltage on connection cables by means of a special meas-
ure equipment.
Connect the cables with the terminals in accordance with the installing dia-
gram.
Install SRP-03 device in installation cable box.
Switch on the power supply from the mains.
Caution: connection of wired switches (LOCAL/CENTRAL) is optional.
RADIO TRANSMITTERS PROGRAMMING
Press PROG push-button of SRP-03 device for a longer time until LED red
diode switches on (constant signal). Next release PROG push-button.
Press and release transmitter's first push-button (movement ▲). LED red di-
ode switches on (first signal pulsates, next the signal is constant).
Press and release the second transmitter's push-button (movement ▼). LED
red diode switches on (signal pulsates) and then switches off - THE TRANS-
MITTER IS ADDED.
An exemplary programming procedure. The procedure for the all radio EXTA
FREE transmitters is analogous.
RADIO TRANSMITTERS DELETION
Press PROG push-button of SRP-03 device for a longer time.
After 5 seconds LED red diode switches on (signal pulsates) and then it switch-
es off.
Release the push-button in SRP-03 - MEMORY IS DELETED.