Troubleshooting
Error indications
HEATING
Temperature sensor
indicator light
under the oil tank
flashes twice
is either shorted-
continuously
circuited or open-
circuited. Buzzer
alarms.
HEATING
Input voltage
indicator light
exceeds the allowed
flashes 3 times
Max/Min rating
continuously
HEATING
Temperature sensor
indicator light
in the oil tank is
flashes 4 times
either shorted-
continuously
circuited or open-
circuited. Buzzer
alarms.
Fault
Appliance not
The unit is not switched on
working
Plug or lead is damaged
Fuse in the plug has blown
Power supply
Appliance stops
Safety switch is activated
working suddenly
Appliance does
Faulty thermostat
not reach set
Faulty element
temperature
Build-up of fat on the element
Appliance heats up
Indicator light has expired
but indicator light
does not come on
Power indicator
Faulty thermostat
light comes on but
Faulty element
appliance does not
heat up
Thermostat set incorrectly
Appliance slow to
Build-up of fat in the tank
heat up
CP793_CT012_ML_A5_v5_20210430.indb 7
CP793_CT012_ML_A5_v5_20210430.indb 7
Description
Probable Cause
Temperature sensor
is defective
Electrical installation
is not in order
Temperature sensor
is defective
Probable Cause
Solution
1. Unit overheated.
2. Let it cool.
Note: If it occurs frequently, call
BUFFALO agent or qualified technician
Have a qualified electrician check it.
1. Unit overheated.
2. Let it cool.
Note: If it occurs frequently, call
BUFFALO agent or qualified technician
Solution
Check the unit is plugged in correctly and
switched on
Call BUFFALO agent or qualified Technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Clean the appliance
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Check and re-set the thermostat