Herunterladen Inhalt Inhalt Diese Seite drucken

Description Of The Appliance - Geba Tronic Cody Light 2 Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Dear customer,
The Cody which you have purchased is one of our highest quality technical pro-
ducts. We have taken the greatest care in its manufacture to ensure that this
microprocessor controlled encoder reaches you in faultless condition. However in
the unusual event of suspected equipment failure please return the appliance
together with the enclosed warranty document to your dealer or direct to our
factory.
The extent of warranty exclusively refers to the free repair of malfunctions of the
appliance, which demonstrably are caused by faults in production or defective
material, inclusive of spare parts required for this purpose.
Therefore please first read the instructions of use carefully before you start
programming !!!
Warranty-document
On the below described encoder we grant a warranty of
Type:
TCS - Cody - Light 1/2
Production date: ____________________________________________________
Sales date:
____________________________________________________
Dealers adress:
industrial controls
2 years
®

Description of the appliance

The TCS-Cody-Light 1/2 consists of a decoder and a keypad. These units are connected by
a simple double-wire cable without a special plug. The appliance connected, in most cases
a door drive, is controlled by the input of a correct pass code.
Pass code:
The pass code is either a four- or five-digit numeral code, by which you operate your
door drive unit. You have the possibility to store up to four different pass codes, which
means that up to four different persons with different pass codes can open the door. In case
you are accompanied by another person when entering your passing code you can at
first press as many keys as you like before you finally enter your code. This ensures that
no other person can notice your pass code. Nevertheless, the TCS-Cody recognizes your
pass code as correct! The input of the pass code is generaly quitted by pressing the key
push button.
Blocking function:
For reasons of safety during attempts of manipulation the TCS-Cody -Light automatically
blocks for 10 seconds after the input of a wrong pass code which is signalled with a
double sound signal. The end of the blocking time is signalled by a long sound signal.
Programming:
The appliance is programmed with four possible pass codes. The logic unit is fitted with
DIP SWITCHES (see figure below). These four switches correspond to the four memory
locations for the individual pass codes. In order to input a pass code set the correspon
ding switch to programming position (ON-position). At the keypad now enter the desired
four- or five-digit new code and actuate the key push button. Then set the switch back to
normal operating position, and test the new code. The relay now activates and the door
opens. Any previously stored code in this position is now overwritten. This procedure can
now be repeated for the other three codes.
Tiptomatic:
Especially for garage doors the TCS-Cody is designed with TIPTOMATIC-timing. After
input of a pass code and within a period of 60 seconds this function allows to control the
door with any key, except for the "KEY" button, and without the need to enter the pass
code once again. This isolating facility can, however, be interrupted prior to the expiration
of the 60 seconds, by pressing the "KEY" button.
Attention: The pass codes stored with the DIP Switches 1 and. 2 activate door 1.
Those with DIP switches 3 and 4 activate door 2.
Connection diagram:
keyboard
DIP SWITCHES
DIP-Schalter
ON
Trans-
Trafo
former
1 2 3 4
power supply
Spannungsversorgung
je nach Gerätetyp
L1 N PE
garage door 2
garage door 1
Tor 2
®
industrial controls
Tor 1

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cody light 1

Inhaltsverzeichnis