NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING POINTS
WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT
• Before any opera�on on the float remember to disconnect the power supply from the main power.
• Check that the maximum motor power does not exceed the float's electrical values.
• In case of cable damage by the final user or installer, the float must be replaced.
• Do not make any joint on the cable of the float switch, as immersion of such joints could cause short circuits or
electrical shocks.
• The maximum slope for proper func�oning is 3° (Fig.1)
USE:
The float is a level controller that allows the user to bring the water levels at certain heights with a minimum and
maximum range (Fig.2): increase or decrease the distance between the floa�ng units of maximum (a) and minimum
(b) level unscrewing the screw (c) fastened to the floa�ng unit by means of a screwdriver with cross head and screwing
with force. Make sure that the floa�ng unit is locked securely. The water will act on the floa�ng body when it is
approximately half of this. It's possible to set the opera�on of the float in automa�c (ON / OFF) or manual (always ON)
via the manual switch on the head of the float (d).
The tank fills
The water reaches the
max level. and it raises
the whole floa�ng body

TECHNICAL FEATURES:

• Protec�on Grade: IP68
• Features of automa�c ac�on: 1B (micro-disconnec�ons in opera�on)
• Pollu�on Degree: 2

TERMINAL CONNECTIONS:

The upstream circuit must protect the electric wires from the overcurrent. WARNING: lack of protec�on shall null
and void the warrany in the event the float breaks
The grounding wire is always yellow and green.
• Emptying: (Fig.3) when black and brown wires are used, the circuit opens when float is down and closes when the
float is up. Note: the blue/grey wire must be insulated.
• Filling: (Fig.4) when black and blue/grey wires are used, the circuit closes when float is down and opens when the
float is up. Note: the brown wire must be insulated.
L
N
High level starts the
pump and the tank
Fig.3 emptying
Blue
Black
Brown
Yellow/Green
M
ENGLISH
max
ON
The water reaches the
minimum level and the
drains
weight of the floa�ng body
disengages the magnet
Fig.4 filling
L
Black
Blue
N
M
min
Brown
Yellow/Green
OFF
Low level stops the
pump