Adjusting the float switch

When the water level rises, it lifts the float switch until the switch-on point is reached and the pump switches on.
When the water level drops, the float switch lowers until the switch-off point is reached and the pump switches off.
 C
• Push the float switch cable into the cable clip.
– The shorter the cable between the float switch and the cable clip, the lower the switch-on point and the higher the
switch-off point.
N O T E
To ensure faultless function, ensure that the length of cable between the float switch and the cable clip
measures at least 10 cm.

Installing the pump

 E
• Install the pump in a horizontal and stable position in the water.
• If it needs to be lowered into a well or a shaft, fasten a rope to the handle. Do not carry it by the power connection
cable.
• Install the pump such that it does not take in dirt particles with a size >25 mm, which would block the intake. Install
the pump in a raised position if necessary.
• Ensure that the float switch can always move freely.

Operation

W A R N I N G
Serious injury or death if the unit housing or electrical components are damaged. A damaged unit in the water
can cause hazardous electrical voltage in the water.
• Never use a unit if it is damaged.
• Never use the unit when persons are in the water.
N O T E
Do not use the unit for long-term operation. Otherwise this will impair the operating life of the unit accordingly.
Switching on the unit
• Insert the power plug into the socket.
– The pump is ready for operation.
– The pump will start up as soon as the level of the water reaches the switch-on height.
Switching off the unit
• Disconnect the power plug.
– When the pump is switched off, residual water in the hose may flow back and out of the pump intake.
N O T E
Rinse out the pump with clean water after use.