FUNCTION
DIP SWITCH
Limit mode
setting
Limit switch direction
setting (J1)
Infrared
mode set-
ting
CAUTION
Auto close
time
setting
CAUTION
Auto close
time setting
when
pedestrian
mode
activated
CAUTION
Condomi-
nium mode
setting
CAUTION
Remote
buttons
mode
CAUTION
Dip 1/OFF
NC mode(Factory setting)
Dip 1/ON
NO Mode
Normal : Short circuit cap simultaneously No1 and No2 of J1 (Factory setting)
If motor system install at left of gate . Please adjust the J1 ,short the cap simultaneously No2 and No3
Dip 2/OFF
NC mode(Factory setting)
Dip 2/ON
NO Mode
If the gate meet obstacles during closing, It will auto stop and auto open. After The gate complete
open to its place, it will auto close again if the obstacle disappear within 2s, if not , it will not auto
close until to the obstacle disappear
Dip 3&4 all
Auto close function disabled (Factory setting)
in OFF
Dip 3/ON &
10 S
4/OFF
Dip 3&4 all
60 S
in ON
Dip 3/OFF
30 S
& 4/ON
Auto close function activated after gate complete open to its place and stop by limit switch
Dip 5&6 all
Auto close function disabled(Factory setting)
in OFF
Dip 5/ON &
5 S
6/OFF
Dip 5&6 all
30 S
in ON
Dip 5/OFF
10 S
& 6/ON
1.When the motor is running, the motor will stop immediately if triggers pedestrian mode
2.After triggering the pedestrian mode to open the gate for 6s, no mater it enter the countdown to close
the gate or stop status, If trigger again, the gate will close the gate immediately.
Dip 7 OFF
Condominium mode disabled(factory setting)
Dip 7 ON
Condominium mode activated
When the gate is opening, trigger remote control and the start interface are invalid until the door is
opened.When the gate is closing, trigger remote control and the start interface , the gate will stop
to close and auto open until the opening limit is reached (the remote control and the start interface
are invalid when the gate is opening).
Dip 8 OFF
Single button control circularly,First button control gate open,stop, close, second
button use for pedestrian mode(factory setting)
Dip 8 ON
Please choose the remote control mode firstly before remote control code clearning to control
board
MODE
EN