OPERATING INSTRUCTIONS
RIGID CAMERA
ITEM NO.: 103552
17.8 cm / 3.9 mm
ITEM NO.: 103553
43.2 cm / 3.9 mm
ITEM NO.: 103556
17.8 cm / 5.5 mm
ITEM NO.: 103557
43.2 cm / 5.5 mm
INTENDED USE
This product serves as a camera attachment for endoscopes BS-500 and BS-1000T (both not included
in delivery) for visual fault tracing or inspection with dead-voltage systems and equipment. The four LEDs
built into the camera head enable shooting in total darkness, with brightness controlled via the connected
endoscope. The waterproof camera neck and camera head are ideally suited for dead-voltage fluids (no
acids or alkaline solutions). The enclosed 45 degree tube allows you to view unreachable areas. Use on
humans or animals, or in explosive areas, is not permitted. Power is supplied via the connected endoscope.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If you use the
product for purposes other than those described above, the product may be damaged. In addition, improper
use can cause hazards such as short circuiting, fire, electric shock etc. Read the instructions carefully and
keep them. Make this product available to third parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company names and
product names are trademarks of their respective owners. All rights reserved.
DELIVERY CONTENT
• Camera
• Protective cap
• Carrying case
• Spiral extension cable
• 45 degree mirror tube
• Handle
• Cleaning kit
• Operating instructions
SAFETY INSTRUCTIONS
Read the operating instructions carefully and especially observe the safety information.
If you do not follow the safety instructions and information on proper handling in this
manual, we assume no liability for any resulting personal injury or damage to property.
Such cases will invalidate the warranty/guarantee.
a) Persons / Product
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may become dangerous
playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high humidity,
moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and protect it from
any accidental use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage
the product.
• Also observe the safety and operating instructions of any other devices which are connected
to the product.
• Observe the statutory regulations relating to the use of the product. Do not use the product for
the surveillance of people, buildings and vehicles!
b) Miscellaneous
• Consult an expert when in doubt about operation, safety or connection of the device.
• Maintenance, modifications and repairs are to be performed exclusively by an expert or at a
qualified shop.
If you are not sure about the correct connection or use, or if questions arise which are not covered by these
operating instructions, please do not hesitate to contact our technical support or another qualified specialist.
OPERATION
Only immerse the camera head and camera neck in liquids that are voltage free! The
camera neck is not to be submerged further than the marking "MAX Water Level".
The endoscope may only be used for inspection of dead systems. The camera head is
made of metal and can lead to short circuits. For safety reasons, disconnect all system
parts from the power supply before every inspection.
Avoid strong mechanical strains or vibrations.
Put the protective cap back onto the camera lens when the camera is no longer in use.
VERSION 03/15
1. Plug the connecting plug at the top of the endoscope carefully into the connecting socket of the spiral
extension socket.
Make sure that the connecting socket is oriented exactly towards the pins of the connecting plug.
There is an arrow printed on the connecting socket. This arrow must point towards the display of the
endoscope.
2. Turn the mounting ring clockwise to fasten the connection.
3. Connect the other end of the spiral connection cable to the socket at the bottom of the camera.
4. Screw the handle onto the side of the camera. Note the correct orientation of the handle, as it is only
possible to screw the handle in from one side.
5. Remove the protective cap before use.
You will find notes on controlling the brightness of the LEDs in the operating instructions of the manual.
6. Follow these steps in reverse order when disconnecting the camera from the endoscope.
7. Replace the protective cap after use.
USING THE 45 DEGREE MIRROR TUBE
1. Insert the 45-degree mirror tube from the top of the camera.
2. Screw the tube in until it reaches the desired direction.
CLEANING
• To clean the camera lens, use a small brush or cotton swab.
• To clean the camera neck, use a cloth lightly dampened with lukewarm water.
• Cleaning materials can be found in the supplied cleaning kit.
DISPOSAL
Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product according to the relevant statutory regulations.
TECHNICAL DATA
Image sensor ............................................. 320 x 240 pixels (item no.: 103552, 103553)
Camera lighting ......................................... 4 white LEDs
Exposure ................................................... automatic
White balance ............................................ fixed
Operating / storage temperature ............... -20 to +60 ºC
Operating / storage humidity ..................... max. 95 %
Protection class ......................................... IP67
Field of view ............................................... 60º (item no.: 103552, 103553)
Depth of field ............................................. 20 – 60 mm (item no.: 103552, 103553)
Cable length .............................................. 2 m
ø ................................................................ 3.9 mm (item no.: 103552, 103553)
Length........................................................ 23.8 cm (item no.: 103552, 103556)
Weight ....................................................... 230 g (item no.: 103552), 250 g (item no.: 103553)
Legal notice
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the
time of printing.
© Copyright 2015 by Conrad Electronic SE
640 x 480 pixels (item no.: 103556, 103557)
2500 lux/15 mm (item no.: 103552, 103553)
1000 lux/20 mm (item no.: 103556, 103557)
54º (item no.: 103556, 103557)
15 – 50 mm (item no.: 103556, 103557)
5.5 mm (item no.: 103556, 103557)
48.8 cm (item no.: 103553, 103557)
240 g (item no.: 103556), 260 g (item no.: 103557)