Herunterladen Inhalt Inhalt Diese Seite drucken

Beschreibung Der Exportierten Daten Im Ascii-Format - IML RESI PD-Serie Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

56

Beschreibung der exportierten Daten im ASCII-Format:

1. Device Code (0F02=PD-Series)
2. File version
3. Machine serial number
4. Firmware version
5. Serial number of electronic components
6. Hardware version of electronic components
7. Machine Memory ID
8. Measurement number
9. ID number
10. Remark
11. Measurement recording year
12. Measurement recording month
13. Measurement recording day
14. Measurement recording hour
15. Measurement recording minute
16. Measurement recording second
17. Number of samples per mm
18. Number of samples amplitude
19. Maximum drilling depth machine (cm)
20. Depth Mode
21. Preselected drilling depth (cm)
22. Drilling depth (cm)
23. Feed speed (cm/min)
24. Needle speed (rpm/min)
25. Offset feed motor
26. Offset drill motor
27. Maximum feed amplitude (load)
28. Maximum drill amplitude (load)
29. Abort State
30. Feed data enabled (0=no, 1=yes)
31. Needle check enabled (0=no, 1=yes)
32. Needle check result (0=worn, 1=ok)
33. Tilt sensor enabled (0=no, 1=yes)
34. Tilt sensor relative mode (0=off, 1=on)
35. Tilt sensor relative angle (degree)
36. Tilt sensor angle (degree). Horizontal=90.
37. Diameter (cm)
38. WoodInspector installed (0=no, 1=yes)
39. WI State (0=WI off, 1=WI on)
40. WI Program (0=Standard, 1=Pole)
41. WI SP Tilt correction (0=off, 1=on)
42. WI SP SSD Settings, State (0=off, 1=on)
43. WI SP SSD Settings, Data source (0=drill data, 1=feed data)
44. WI SP SSD Settings, Entry level (%)
45. WI SP SSD Settings, Maximum entry depth (cm)
46. WI SP SSD Settings, Piercing mode (0=partial, 1=full)
0=No depth preselected
1=Fixed depth preselected
2=WoodInspector diameter detection
3=WoodInspector entry detection
4=WoodInspector entry/exit detection
0=System error
1=Preselected drilling depth reached
2=Maximum drilling depth reached
3=Safety pin released
4=Cancelled by user (button pressed)
5=Battery empty
6=Undervoltage detected
7=Feed motor overload
8=Feed motor blocked
9=Drill motor overload
10=Drill motor blocked
11=Automatic needle retraction
12=Needle exit detected (WoodInspector)
13=Emergency stop (knob pressed)
IML-RESI PD-Serie

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis