The PRS300 charge regulator can automatically charge the following
using the
correct
charge line (which can be selected with the switch
regulator): lead-gel, lead-acid, AGM and lithium batteries (with integrated electronics .
The charging procedure occurs in three steps:
Step 1:
Battery charge
charge voltage is reached.
NOTE: the end of charge voltage is reached only if
Step 2:
Battery charg completion
reduction.
Step 3:
Maintenance
The cycle starts again when the battery voltage is lower than 13Vd.c., such as in the case of
equipment turning on.
Note:
an
uneven exposure to sunlight may lead to varying charging times.
A desulfation function
Position the selector on the end of charge voltage recommended by the battery
manufacturer.
Generally, the selector should be set on position "A" for lead-acid batteries, position "B" for
lead-gel batteries, and position "C" for AGM and lithium batteries.
STEP 1 -
END OF CHARGE VOLTAGE
-
-
STEP 2 -
CHARGING COMPLETION
STEP 3 - MAINTENANCE VOLTAGE
- The
device
shall be used for the regulation of
Connection to other equipment which can damage
warranty void.
- The regulator must be exclusively used with the types of batteries listed above The kind of
battery to charge shall be set on the solar regulator internal board using the
(see page ); the wrong setting of the battery to charge may damage the battery itself!
8
Note: the PR
S300 r
lithium batteries without integrated electronics or other kinds of rechargeable or non
rechargeable batteries.
- The regulator is not suitable for external use.
- Install the regulator in an appropriate dry and ventilated housing; make sure there is a
minimum distance of 300mm from the front and 100mm from the sides
surrounding surfaces.
- Do not cover
the
air intakes on the lid.
- The
device
produces heat during
equipment near the instrument does not hamper the correct air flow and prevent the
necessary instrument cooling.
- Use cables with
an
recommended).
- Protect the cable from any possible damage.
s
- Protect the 12V battery line using a suitable fuse to be placed close to the battery.
with
the maximum current of the photovoltaic module
- -
e
at the end-of-charge voltage with
at
a
constant voltage.
is automatically activated when required by the battery
TIME
egulator is not suitable for the charging of nickel/cadmium batteries,
its
normal operation. Make sure that the installation of other
appropriate section ( 6mm² section for
the
Position "A"
14,1 V
1h
13.5 V
12V
photovoltaic modules charging only.
its
correct operation may result in
a
each
12V
d.c. batter
placed
inside the
, until the end of
batteries are efficient.
a gradual current
.
Position "B"
Position "C"
14,3 V
4h
13.8 V
.
apposite
of the device
photovoltaic module
y types
)
- -
14,7 V
2h
13.8 V
selector
to the
is
GB
6