Blinking Green Light in the
back of unit
Fan making a loud noise
Unit doesn't cool contents
as advertised.
• Unit not cooling and
light off in the back
• Unit stopped working
• Ice is building inside the
unit, around the center
screws in the back.
• Water collecting at the
bottom of the unit.
• Water drip or leakage.
1. Please confirm the sockets and the power cords to be tight when the fridge does not work; A loose
socket will result in the cords and sockets over heating and possible damage to the item
2. Please make the following measures if the cooling effect is not good:
a. Ensure the ventilation surrounding the item is sufficient 10cm in all sides and above the item.
b. Ensure the door is closed as much as possible and the temperature if recorded is done so from
the center rear of the shelf.
c. Check the switch is in the correct mode and the corresponding Green / Red Light is illuminated.
d. If overworked the unit may need to be powered off to reset, switch off for 1 hour and re-select
the cooling or heating mode and power input in AC or DC
e. If the fan is faulty or there is no cooling effect at all. Please contact a professional for repair.
The most common issues experienced by Subcold users are caused by
voltage issues . The following problems give an overview of possible
errors and instructions of how to check the unit.
POSSIBLE REASON
Unit fan not rotating
Check for fan obstruction or failure
Most Subcold Units cool contents down
anywhere from 16-20 degrees
Main power source failure
• Check that the door is clean and free
from obstruction and is closed securely.
• Water Condensation. It is normal for
thermo-electric units, while in cooling
mode, to produce water droplets that
may freeze in the back and then melt.
• Water condendsation is normal in a
thermo-electric unit. Check if water
accumulation is due to condensation.
Contact Customer Support for assistance.
Consult this user manual or go to
subcold.com
Check the back to see if there is at least 10cm
clearance around fan and vents. If issue persists,
contact Customer Support.
Consult your Unit's specific cooling information
found in this user manual. If cooling
temperature is significantly less than what is
listed for your unit, contact Customer Support.
Check outlets first.
If unit is not turning in your home/office: Try
plugging the unit in to your car using the DC
power cord.
If unit is not turning on in your car/motor
vehicle: Try plugging the unit into a 100-120
volt outlet in your home/office using the
included AC power cord.
If problem persists, contact Customer Support.
While the unit is off and at room temperature,
take a soft cloth and gently wipe down the
inside of your unit to remove any moisture that
may accumulate.
This is recommended once or twice a week
If issue persists, contact Customer Supports for
assistance