*To install the Chorus line (Gewiss) remove the fins from the Frame B (see the picture)

Cut out for Touch SFT Multifunction control panel:

4.6

Tank sensors

The sensor wiring of the control units, both in the standard one-level version (grey / black),
and in the two-level version for Touch (red / black and white / green) have a voltage of 7V.
You can connect:
• Sensors with clean contact (float, with pressure switch or similar) which close the
contact between the two poles of the connector.
• Electronic sensors with the following specifications:
o Power 7V.
o Electrical absorption 12,75 mA +/-1 mA when the sensor is un-activated and
22,75 mA +/- 1 mA when activated.
WARNING: In any case, do not connect the sensor cable to any power source.
NOTE: For the compatibility of the control units with other types of sensors or for the
use of connections other than those indicated in the wiring diagrams, contact the
Tecma S.r.l.