Product description:
The headends convert IPTV transport streams (SPTS and MPTS) into DVB-T2
output channels.
IPTV
Configuration
Coax
Equipotential bonding
Ethernet switch
MIE 6-02
MIE 3-02
Includes 1 module, supports SPTS and MPTS (also mixed),
transmodulates max. 512 input streams in 3 DVB-T2 output
channels.
MIE 6-02
Includes 2 modules, supports SPTS and MPTS (also mixed),
converts a maximum of 2 × 512 input streams into 2 x 3 DVB-T2
output channels.
Scope of delivery:
1 × IP to DVB-T2
2 × AC power cord (MIE 8-00, MIE 16-00 and MIE 32-00 only)
1 × Quick start guide (You can call up the detailed operation instructions for
download by entering the article in the search field at www.axing.com)
Available Accessories
MIM 3-02 Extension module for MIE 3-02 or MIE 3-02/48 for extension to
2 × 512 input streams and 2 x 4 DVB-T2 output channels.
MIS 1-11
Software extension for MIE device redundancy
Offers the possibility to replace a device with another device, e.g.
in case of failure.
MKS 1-02 Software extension for CASimulcrypt
Offers the possibility to encrypt programmes.
Connectors
CAS interfaces*
IPTV inputs
Redundant IPTV inputs
CAS interfaces*
Equipotential bonding connection
2 × redundant power supply units
Test ports
* The ports CAS/IN2, IPTV IN1 and Control can be configured as the interface for the CAS server.
Mounting and Installation:
 Before mounting and installation, pull the mains plug!
Mounting in a 19" rack
For 19-inch rack mounting, there must be at least 5 cm clearance in front of
and behind the unit.
 Slide the device into the 19 „rack.
 Fix the device with four screws.
Equipotential bonding
 The device must be connected to the equipotential bonding according to EN
60728-11.
 Use the equipotential bonding connection at the device.
 To connect the outer conductor of the coaxial cable to the equipotential
bonding, use e.g. QEW earthing angles or CFA earth connection blocks.
Power supply 100...240 VAC
 Connect both power supplies with the enclosed cables to 100...240 VAC.
Power supply 36...60 VDC
 The power supply input connectors are 2 × M4 screws
 Connect the DC connectors to 36...60 VDC.
 Important: Ensure that the polarity is correct. Use sufficient conductor cross
sections.
IPTV input
 Connect the IPTV input to an Ethernet switch connected to the IPTV source.
Use Class 5/6 Ethernet cables with RJ-45 connectors.
RF output
 Connect the output (RF OUT) of the device to the established distribution
network. Use a high-shielded coaxial cable with an F connector.
Upgrading a MIE 3-02:
The MIE 3-02 can be extended by a further module MIM 3-02.
 Disconnect the device from the mains.
 Disassemble the cover plate on the back.
 Insert the module carefully.
 The module noticeably snaps into the contacts.
 Screw the module with the screws of the cover plate.
 Then reconnect the device.
 Configure the new module in the same way as module B in the MIE 6-02.
Display elements
Configuration interfaces
CAS interfaces*
RF outputs
LEDs 1...3
of modul B (MIE 6-02)
The LEDs show the state of the output modulators:
9 When a modulator is filled with content and the modulator is not over-
loaded, the corresponding LED lights up green.
9 If a modulator is on but not filled (without content), the corresponding
LED flashs.
9 If a modulator is overloaded (too much content), the LED lights up red.
9 In case a modulator is turned off, the corresponding LED is off.
Configuration:
The device is configured via the graphical user interface. To access the
user interface, you need a standard PC/laptop with a network interface, a
commercially available network cable and the actual version of the installed
web browser.
The MIE 3-02 includes one module A
 Default IP address of module A:
 Subnet mask:
The MIE 6-02 includes two modules A and B. Each module has its own
configuration interface and its own IP address.
 Default IP address of module A:
 Default IP address of module B:
 Subnet mask:
Accessing the configuration interface:
 Change the IP address of your PC/laptop, e.g. to 192.168.0.11, subnet
mask: 255.255.255.0
 Connect the PC to the RJ-45 Ethernet connector Control.
 Enter the IP address of the connected module in the web browser.
The configuration screen is password-protected:
 Enter the default password Ramsen8262 (after the first log-in, the
password should be changed).
 Click the „Enter password" button.
This will open the start page.
 Follow the steps of phase 1, 2 and 3 to configure the device.
LEDs 1...3
of module A (MIE 3-02/6-02)
192.168.0.145
255.255.255.0
192.168.0.145
192.168.0.148