COMMISSIONING
An odor may develop during initial use. This is not harmful. Nevertheless, ensure in particular
that there is sufficient ventilation.
Incorrect use can lead to a build-up of heat and thus damage the unit. Do not operate the unit
when it is placed horizontally or when it is facing downwards. The air inlet opening and the nozzle
must not be covered. Only use nozzles that are suitable for your unit.

OPERATION

Insert the plug of the heat gun into the socket.
The heat gun is started when the switch is pushed up to the "Ⅱ" position for high power or to
the "Ⅰ" position for low power.
The blower is stopped when the switch is pushed down to the "O" position.
The blower must not be touched until it has cooled down.
The heat gun must be stored vertically and upright when not in use.
MAINTENANCE AND CARE INSTRUCTIONS
Always switch off the appliance and disconnect the mains plug before carrying out maintenance
or inspection work.
For safe and efficient operation, always keep the unit and its ventilation slots clean.
Check all the parts for signs of wear. Do not continue to use the product if you find any defects.
Only have parts replaced with original spare parts by a specialist in accordance with the
manufacturer's specifications. A lack of care and maintenance can damage the appliance.
Dangerous situations can arise. To ensure electrical safety, the appliance must not be treated
with or even immersed in liquids. Regular maintenance helps to ensure the safety of the product
and increases its service life.

TECHNICAL DATA

Power supply
Frequency
Rated power
Temperature / flow rate stage 1
Temperature / flow rate stage 2
230 V
50 Hz
2000 W
350°C / 300 l/min
550°C / 500 l/min
15