Note
During installation, the adapter must be used as a straight-pipe length between the shutoff valve and the flowmeter. Observe the arrow
marking on the flowmeter indication the correct direction of flow. Use only a sealing compound appropriate for the pipe diameter, so that
the water will flow without any additional turbulence. Only by observing these instructions can the flowmeter provide the correct values.
Disconnect the machine from the electrical supply and the gas supply (if required) and secure against resetting.
Connect the flowmeter to a
Connect the flowmeter to a water intake hose or Y-piece. See Fig. 2.
Note
PW 6101, PW 6131, PW 6161, PW 6201:
Remove the electrical connection cover on the rear of the machine.
Electrically connect the flowmeter in accordance with the MF 07 wiring diagram.
Replace the electrical connection cover on the rear of the machine.
Note
PW 6163, PW 6243, PW 6323:
Remove the cover from the connection box.
Connect the flowmeter to the terminal block in accordance with the wiring diagram.
Replace the connection box cover.
Check the newly installed parts for leaks (at the water connection).
Test for correct function.
Reconnect the machine to the electrical supply and the gas supply (if applicable).
Note
PW 6101, PW 6131, PW 6161, PW 6201:
Register the MF 07 module via the service mode (procedure may vary depending on software ID). Example: Service
Settings Register module MFM with code 7 Diskette symbol (to save the registration). Or: Service Settings
Register module EZL with code 7 Register module? OK Diskette symbol (to save the registration).
Activate flow measurement for the applicable flowmeter (number 1, in this example) via service mode: Service Settings Basic
settings Water intake Impeller Impeller 1: No Yes OK (back to Impeller 1: Yes )
symbol appears) Diskette symbol (to save the activation for flowmeter 1).
Note
For software IDs 1000/1001 and later, back up the data manually.
Back up data via service mode: Service Backup Back up BAE data Overwrite existing data? Diskette symbol
(to overwrite BAE data).
To exit service mode, switch off the machine.
Perform a function test, e.g., by starting a wash program. The program should take in water via the appropriate flowmeter. If no fault
message appears in the display, then the flowmeter is functioning successfully.