Herunterladen Diese Seite drucken

Hammerbacher XDSM Serie Betriebsanleitung Seite 2

Reset-pfl icht vor inbetriebnahme
Vorschau ausblenden Andere Handbücher für XDSM Serie:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

XDSM/ XBHM series:
Status at 03/2020/ English 114063
RESET obligations prior to initial operation:
RESET obligations prior to initial operation:
- The table must be in the correct position before initial operation.
- The power must be connected before initial operation.
- A reference drive (Reset) must be carried out on the table before initial operation.
For this proceed as follows:
RESET :
After longer operation of the table it is possible for slight lift diff erences to occur between the
columns (the table is slightly 'tilted'). This diff erence in height is resolved by carrying out a RESET
drive.
Please repeat the reset at regular intervals, e.g. 1x per month!
Please retain these instructions!
2
Press the „DOWN" button on the control unit and move the table to the
lowest position (release the button again).
Press the „DOWN" button on the controls and hold it down. After
10 seconds the table will move to the lowest position and a small 'click'
can be heard.
If the button is released before the process is complete then the RESET
process is interrupted and must be started again.
The collision protection is not active during all RESET processes!
Please observe the safety notes!