Herunterladen Diese Seite drucken

Klaxon PSS-0084 Installationsanweisung

Signalgeber

Werbung

EN
DE
TONE
TONE TYPE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
Type
CPR Reference
PSS-0084
Reference 0832-CPR-F1923
PSS-0089
Reference 0832-CPR-F1923
Technical Data Doc.18-186213
Type A: For indoor use (Shallow Base) Type B: For outdoor use (Deep Base)
Fig. 1a
Texecom Ltd (Incorporating Klaxon Signals)
St Crispin Way, Haslingden, BB4 4PW, UK.
Tel: +44 1706 233879
FR
NL
TONE DESCRIPTION/ APPLICATION
970Hz
800Hz/970Hz @ 2Hz
800Hz – 970Hz @ 1Hz
970Hz 1s OFF/1s ON
970Hz, 0.5s/ 630Hz, 0.5s
554Hz, 0.1s/ 440Hz, 0.4s (AFNOR NF S 32 001 )
500 – 1200Hz, 3.5s/ 0.5s OFF (NEN 2575:2000 Dutch Slow Whoop)
420Hz 0.6s ON/0.6s OFF (Australia AS1670 Alert tone)
1000 - 2500Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF ( AS1670 Evacuation)
550Hz/440Hz @ 0.5Hz
970Hz, 0.5s ON/0.5s OFF x 3/ 1.5s OFF (ISO 8201 )
2850Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201)
1200Hz – 500Hz @ 1Hz (DIN 33 404)
400Hz
550Hz, 0.7s/1000Hz, 0.33s
1500Hz – 2700Hz @ 3Hz
750Hz
2400Hz
660Hz
660Hz 1.8s ON/1.8s OFF
660Hz 0.15s ON/0.15s OFF
510Hz, 0.25s/ 610Hz, 0.25s
800/1000Hz 0.5s each (1Hz)
250Hz – 1200Hz @ 12Hz
500Hz – 1200Hz @ 0.33Hz
2400Hz – 2900Hz @ 9Hz
2400Hz – 2900Hz @ 3Hz
500 - 1200Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF ( AS1670 Evacuation)
800Hz – 970Hz @ 9Hz
800Hz – 970Hz @ 3Hz
800Hz, 0.25s ON/1s OFF
500Hz – 1200Hz, 3.75s/0.25s OFF (AS2220)
Fire Alarm Device - Sounder
Fig. 1b
Installation Instructions
ES
PT
Essential Characteristics
Reproducibility
Operational performance
Durability
Dry Heat (operational)
Dry Heat (endurance)
Cold (operational)
Damp heat, cyclic (operational)
Damp heat, steady state (endurance)
Damp Heat, cyclic (endurance)
SO2 corrosion (endurance)
Shock (operational)
Impact (operational)
Vibration (operational)
Vibration (endurance)
Electrostatic discharge (operational)
Radiated electromagnetic fields
(operational)
Voltage transients, fast transient
bursts (operational)
Enclosure Protection
0832
sales@klaxonsignals.com www.klaxonsignals.com
16
Sonos DC Sounder
IT
PL
DIP SWITCH
2nd
1 - 2 - 3 - 4 - 5
O - O - O - O - O
18
O - O - O - O - I
1
O - O - O - I - O
1
O - O - O - I - I
1
O - O - I - O - O
4
O - O - I - O - I
1
O - O - I - I - O
1
O - O - I - I - I
9
O - I - O - O - O
1
O - I - O - O - I
19
O - I - O - I - O
1
O - I - O - I - I
1
O - I - I - O - O
1
O - I - I - O - I
18
O - I - I - I - O
1
O - I - I - I - I
1
I - O - O - O - O
1
I - O - O - O - I
1
I - O - O - I - O
18
I - O - O - I - I
19
I - O - I - O - O
19
I - O - I - O - I
1
I - O - I - I - O
1
I - O - I - I - I
1
I - I - O - O - O
1
I - I - O - O - I
18
I - I - O - I - O
18
I - I - O - I - I
8
I - I - I - O - O
1
I - I - I - O - I
1
I - I - I - I - O
1
I - I - I - I - I
8
Declared Performance
EN54-3:2001+A1:2002
A2:2006 Subclause
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11
5.12
5.13
5.14
5.15
5.16
5.16
5.16
5.17
Issue 21 (Nov 2016) INS533-21
Copyright © Texecom Ltd.
SE
DK
dBA @ 1m
mA
99
17
100
16
100
16
99
10
99
15
97
9
99
12
96
5
104
10
97
10
98
8
94
17
99
13
95
9
98
13
104
30
99
14
106
41
96
13
96
8
96
7
98
11
100
17
98
9
99
14
101
36
104
36
98
6
99
16
100
6
99
4
99
13
TYPE A TYPE B
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
N/A
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS

Werbung

loading

Inhaltszusammenfassung für Klaxon PSS-0084

  • Seite 1 Voltage transients, fast transient 5.16 PASS PASS bursts (operational) Enclosure Protection 5.17 PASS PASS Texecom Ltd (Incorporating Klaxon Signals) Issue 21 (Nov 2016) INS533-21 St Crispin Way, Haslingden, BB4 4PW, UK. Copyright © Texecom Ltd. 0832 sales@klaxonsignals.com www.klaxonsignals.com Tel: +44 1706 233879...
  • Seite 2 Sonos Basic Wiring Diagrams Wiring the sounder 1. 9-60V DC Sounder-Only From Controller To Next To Next Sounder From Controller or EOL or EOL Device ( 1 ) ( 2 ) ( 3 ) ( 4 ) ( 1 ) ( 2 ) ( 3 ) ( 4 )
  • Seite 3 Installation Manual Installationsanweisung Installation Installation If required, the mechanism for locking the sounder to the base Um den Signalgeber im Sockel zu arretieren, ist das can be activated by removing the thin section of plastic shown Sicherungsplättchen im Gehäuse zu entfernen. Dies kann in Fig.
  • Seite 4: Notice D'instructions

    Notice d’instructions Montageinstructies Certification NF Montage Indien nodig kan het mechanisme om het alarm aan de basis te Seules les modèles avec une des références commerciales vergrendelen worden geactiveerd door het verwijderen van het suivantes sur leur tête et ayant l’estampille NF sont certifiées NF: dunne stukje plastic met een tang of vergelijkbaar gereedschap No.
  • Seite 5: Instrucciones De Instalación

    Instrucciones de Instalación Manual de Instalação Instalación Instalação Active el mecanismo de seguridad si esto fuera necesario, para Se necessário, o mecanismo para fixar o sensor à base pode evitar que la sirena pueda ser desconectada de la base. Para ser activado removendo a fina película de plástico ilustrada na Fig.
  • Seite 6: Istruzioni Di Installazione

    Instrukcja montażu Istruzioni di installazione Installazione Instalacja Se necessario, è possibile attivare il meccanismo di bloccaggio del W razie potrzeby mechanizm blokujący głośnik na podstawie segnalatore acustico alla base rimuovendo la sottile linguetta di można uruchomić, usuwając cienką warstwę folii pokazaną na Rys. plastica illustrata nella Fig.
  • Seite 7 Installationsmanual Installationsanvisninger Installation Installation Om så behövs, kan mekanismen för att låsa summern vid basen Om nødvendigt kan mekanismen for aflåsning af lyd alarmen til aktiveras genom att avlägsna den tunna plastbiten, såsom visas underlaget aktiveres ved at fjerne det tynde plastik lag, som vist i Fig.

Diese Anleitung auch für:

Pss-0089Pss-0003Pss-0039Pss-0020Pss-0050