Error-Checklist:

Problem
Spray pattern shows strings
and/or is uneven
"Sputtering" spray pattern
Liquid runs out, although
the needle is closed.
Liquid runs into the
control air distribution
Stand 15.10.2008
Reason
Twist body polluted
Liquid insert polluted
Liquid insert and/or air cap are/is
damaged (scratches, deformation
on the outlet-bores etc.)
Atomization air occurs the liquid
channel
Control air occurs the liquid
channel
Wrong assembly of the twist body
Liquid insert and/or needle are/is
gotten dirty
Sealing surface of the liquid insert
and/or of the needle is damaged
Sealing screw is not fitted tightly
and/or O-rings of the sealing
screw are damaged
Verfasser: Stefan Bätz
Elimination
Cleaning of the twist body
Cleaning of the liquid insert
Replace liquid insert and/or air cap
Check liquid insert for a tight fit
Check sealing screw for a tight fit;
check the O-Rings of the sealing screw
for damages and replace them, if
necessary
Correct assembly of the twist body
(see instructions on page 12)
Cleaning of the liquid insert and/or of
the needle
Replace liquid insert and/or needle
Check sealing screw for a tight fit
and/or replace O-rings of the sealing
screw