Herunterladen Inhalt Inhalt Diese Seite drucken

Norsup SUPERNOVA Originalbetriebsanleitung Seite 4

Desinfektionssystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
SUPERNOVA - SUPERNOVA TIMER
Please read through these instructions for use
carefully before installing this device.
HOW IT WORKS
Inside the reactor a UV-C lamp produces radiation
with a wavelength of 253.7 nm. Radiation of this type
kills bacteria, viruses, algae and fungi (e.g. Legionella
and Cryptosporidium). The UV-C unit produces clean,
fresh, clear water in an efficient, environmentally
friendly way. The water is fed through the UV-C device
by a pump. The UV-C radiation neutralizes bacteria,
viruses and other micro-organisms and prevents
them from reproducing. Floating algae is also
destroyed by this radiation, which greatly improves
the clarity of the water. The UV-C unit is equipped
with an electronic ballast. This ballast ensures
optimum performance of the lamp.
In addition, the stainless steel reactor reflects the
UV-C radiation, increasing efficiency by up to 35 .
Thanks to the UV-C unit, the water is disinfected
efficiently and safely, providing you with excellent
water quality. Overdosing with UV-C is not possible.
INSTALLATION OF EARTHING (FIGURE 1)
1. Before the plastic strain relief (4) is fitted on the
earthing bolt (1), first pull the cable (2) through the
strain relief (4). Place the strain relief (4) about 10 cm
from the eye (2) of the earthing cable.
2. Place the eye (2) of the cable over the earthing bolt
that is attached to the housing.
3. Then place a serrated lock washer (3).
4. Attach the strain relief (4) to create a Ø5 cm loop.
5. Finally, place the second serrated lock washer (5)
and the lock nut (6) on the earthing bolt.
6. Once the parts have been placed on the earthing
bolt in the correct order, it can be tightened with an
8 mm open-end or ring spanner.
WARNING
Always ensure proper earthing. In
case of doubt about the earthing
or the electrical installation in
general, always consult a qualified
electrician. Incorrect earthing can
be dangerous and/or lead to
corrosion of stainless steel or
aluminium reactors.
Make sure the reactor is always
grounded.
6
WWW.NORSUP.EU
DEVICE INSTALLATION (FIGURE 2)
Decide where you want to mount the device. Never
install the UV-C unit after the pH controller, chlorine
dispenser or salt electrolysis system in the swimming
pool installation. The best place to install the device is
directly after the filter. See the schematic diagram in
the operating instructions. Make sure there is always
water flowing through the device when the lamp is
on. Never install the device in direct sunlight. Install
the device in a dry, well-ventilated area. The device
can be installed either horizontally or vertically,
provided that the water flow is from bottom to top
(see schematic diagram at the beginning of the
instructions for use), with 30 cm of unobstructed
space on the side opposite the lamp connection for
future maintenance. At least one metre of
unobstructed space must be left on the side with the
lamp connection for convenient future replacement
of the lamp (K) without having to disconnect the
entire device.
CAUTION: All connections and couplings must be
hand-tight. Do not tighten them with tools.
Otherwise damage may occur.
1. Unscrew the nut (N) from the housing (U). Remove
the UV-C lamp (K) from the supplied tube (see
packaging) and carefully slide the lamp into the
quartz sleeve (M). Place the lamp (K) with the
contact pins in the lamp fitting (L) and then tighten
the nut (N) on the housing (U).
2. Fit the supplied pipe clamps (O). Then insert the
unit into the pipe clamps. Tighten the three-piece
coupling (I) firmly, while ensuring the correct
position of the sealing rings (P), both at the
connections and the quartz sleeve (see figure 2).
3. Mount the unit in the circuit by means of the
three-piece coupling (I) and the glue coupling for the
flow switch (V *For amalgam only). The glue
connections of the three-piece coupling are Ø63 mm
or 2". If the pipes are smaller than Ø63 mm or 2", use
the Ø63 x 50 mm (T) or 2" x 1.5" x 1" adapter. This can
be glued in the three-piece coupling (I) and in the
glue coupling for the flow switch (V *For amalgam
only). The inside of the adapter (T) has internal screw
threads at one end, making it possible to fit a hose
tail adapter (not included) with sealing ring.
4. Insert the plug of the UV-C device into an earthed wall
socket that is protected by a residual current device.
5. Look through the transparent parts of the device to
make sure the lamp is lit.
6. The device is shut off when power is disconnected
from the device.
*For amalgam only
Alterations which serve the technological progress as well as errors excepted!
SUPERNOVA - SUPERNOVA TIMER
7. The glue coupling for the flow switch (V) must be
positioned on the three-piece coupling (I) with the
screw thread (W) facing up (see figure 2). The glue
coupling (V) can be glued to a three-piece coupling
(I). Mount the flow switch (X) which is attached to
the electrical section (S) directly to the screw thread
(U) of the glue coupling (V) (see figure 2). If the flow
switch is mounted differently, the device will not
work. The arrow on top of the flow switch (X) must
always point in the direction of water flow. If it points
in the direction opposite the water flow, the UV-C
device will remain off.
8. When no water is flowing through the device, the
flow switch automatically switches the unit off.
INSTRUCTIONS FOR USE LED HOUR METER
(FIGURE 3. FOR TIMER ONLY)
When the UV-C device is switched on, the program
performs a self-diagnostic test. The LED flashes red
quickly for about one second. Then the LED lights
green, flashes green or lights red. This depends on the
number of hours that the system has already been in
operation.
When the UV-C lamp is switched on for the first time,
or after the 'reset' function is used, the value will be
9,000 or 16,000. The number of hours is based on the
lamp in your device. Each UV-C lamp has a maximum
number of operating hours, during which the lamp
provides optimum disinfection. After this number of
hours the lamp must be replaced. When the system is
switched off, or after a power failure, the system will
remember the remaining number of hours. When it is
switched on again the system will continue counting
from where it left off.
HOUR METER STATUS (S)
• Lit green: the UV-C lamp is operating within its
normal service life.
• Flashing green: the UV-C lamp will need to be
replaced after 500 more hours.
• Lit red: the UV-C lamp should be replaced as soon as
possible.
RESETTING THE HOUR METER
After the lamp is replaced, the system can begin
counting again. First you must perform a 'reset'. A
reset changes the hour meter reading back to the
programmed number of hours.
• Hold the button (R).
• The LED will flash quickly and then light green. This
takes a total of about 5 seconds (S).
• As soon as the hour meter is lit green you can release
the button.
• The hour meter will begin counting a new cycle as
described under 'hour meter status'.
Alterations which serve the technological progress as well as errors excepted!
DISASSEMBLY / MAINTENANCE
Always disconnect the power supply during
maintenance/disassembly of the device.
The device must be cleaned at least twice a year.
When there is a significant amount of algal growth
and/or lime build-up in the unit the quartz sleeve (M)
must be cleaned.
The special lamp must be replaced after the number
of hours of operation has elapsed. The inside of the
reactor can be cleaned with a soft brush.
1. Let the water flow out of the device.
2. Unscrew the nut (N) and remove the lamp (K) from
the fitting (L). Remove the lamp from the quartz
sleeve, and replace the special lamp (K) if necessary.
Caution is advised as these are very delicate parts.
3. Carefully remove the quartz sleeve (M) (see figure 4).
Never use force! CAUTION: Always wear protective
gloves and glasses.
4. Clean the quartz sleeve with an appropriate
cleanser. Always use a soft cloth to clean the sleeve
and avoid scratches.
5. Carefully place the lamp back in the quartz sleeve,
fit the O-ring (T) back onto the quartz sleeve and
connect the lamp (K) to the fitting (L). Screw the nut
(N) back onto the housing.
If the housing or the electrical section must be
replaced, the earthing must first be disconnected
from the housing. Please read the Installation and
Disassembly section before installing a new housing
or electrical section. Make sure you save the various
separate parts for the earth connection. These are not
supplied with a new housing or electrical section. If in
doubt about the connection, consult a qualified
installer.
For the safety instructions and terms of
guarantee we would like to refer to the
general UV-C manual.
ORIGINAL MANUAL NORSUP
EN
NL
DE
FR
ES
PT
RU
7

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Supernova timer

Inhaltsverzeichnis