2. Electrical connection
TERM2000 heat reflectors are adapted for two or three phase supply. All components are adapted
for operation on 230 voltage. Fixed installation should be equipped with off-switches ensuring
disconnection from power supply on all poles (aside from earthing).
Space between poles - minimum 3 mm.
Connection of cables to a connection cube depends on type of reflector and used kind of power
supply: Cross section of cables selects a qualified electrician In accordance with power of reflector
and distances from control board.
NOTE: The power cord must not come into contact with reflector housing.
When the appliance become not usable its utilization must be run in accordance with regulations.
See ELECTRICAL CONNECTION infographic, page 5 and 6
Fixing and setting
The reflectors are mounted onto wall, ceiling etc. using a metal bracket included in the delivery.
• Longer arm of the bracket (with two holes) screw down with pins and bolts at diameter 8 – 12mm
and length 60-80 mm, depending on reflector type (weight).
• Shorter arm of the bracket (with one hole) screw down with bold and pin onto a holder of assembly
jointing.
• Slope angle of the reflector towards a floor set up by blocking the assembly jointing in a specific
position (usually 45°). The housing of the reflector should be positioned parallel towards surface of
wall or ceiling as well as ensure horizontal position of quartz emitter of the reflector.
See FIXING AND SETTING infographic, page 5 and 6