ASSEMBLY INSTRUCTIONS TERM2000 MULTI IP67 RCJ / RCB / RCC
NOTE: Please read the instructions carefully before using the appliance and comply with the
instructions.
Do not touch the halogen emitter with bare hands. If the halogen emitter is inadvertently touched,
remove finger marks deposited in the place with cloth moistened with ethyl alcohol (pure spirit not
denatured alcohol or salicylic spirit). Remained grease residue can cause premature failure of a
reflector emitter resulting in loss of warranty.
All electrical installations must be done in accordance to safety regulations referring to installation of
electrical appliances. If in any doubt, consult a qualified electrician.
CAUTION: The reflector must be earthed.
INSTALLATION
1. Selection of hanging place
Minimum distances of hanging the TERM 2000 reflector from a floor, ceiling and sidewalls depend on
a reflector type (power). The parameters are shown in the below table.
Note: In a reflector code (eg. RCJ 330) the first two letters are abbreviation of the heat reflector. The
third letter stands for a reflector type, depends on configuration and emitters q-ty, next figures
specify reflector nominal power i.e. 330 – 3,3 kW; 400 – 4,0 kW etc. Emitters can work in horizontal
position if in the end of letter name there is "V" means lamp can work in any position.
CAUTION: Do not install reflectors near curtains or any flammable items. Do not place reflectors
directly under a wall socket.
Model:
Rated voltage:
Rated output:
Weight:
Protective system:
Fuse:
Model
„a" min
RCJ 330
3 m
RCJ 400V 3,5 m
RCB 330V 3 m
RCB 400V 3,5 m
RCC 495
3,5 m
RCC600V 4,5 m
RCC
3N 400V 50 Hz
4950/6000 W
6,8 kg
IP67
min. 10 A/phase (slow
blow fuse)
„b" min
0,5 m
0,5 m
0,5 m
0,5 m
0,5 m
0,5 m
RCJ
2N 400V 50 Hz
3300/4000 W
4,5 kg
IP67
min. 10 A/phase (slow
blow fuse)
„c" min
1,5 m
1,5 m
1,5 m
1,5 m
1,5 m
1,5 m
RCB
2N 400V 50 Hz
3300/4000 W
4,5 kg
IP67
min. 10 A/phase
(slow blow fuse)