WATER CONNECTION

Water connection is performed with hose threaded G1/2. The water supply must be equipped with a separate
valve which is freely available and within range of the device. The equipment includes a check valve.
• Water hardness must be in range 0,5 - 5 ° French degree.
IF HIGHER, IT IS NECESSARY USE WATER SOFTENING SYSTEM.
• Water pressure must be within range 50 - 250kPa.
• Volume of chlorine in the water shall not be higher than 10ppm, or you risk bath surface damage
• Acidity of water must be higher than 7 pH.
• Electrical conductivity: 50 - 2000uS/cm (20°C)
• The connection must be made according to directive EN 1717 and with valid to national directives for aqua-
culture.
SAFETY MEASURES FROM THE STANDPOINT OF THE FIRE PROTECTION
• only adults can operate the device
• device must be safely used in common surroundings according to EN 332000-1
• device must be placed so as to stand or hang on the noncombustible surface. No subjects from combustible
materials can be placed directly on the device or in distance which is shorter than safety distance (the
shortest distance is 10 cm).
• safety distances from various materials of different degree of combustion and information about the degree
of comb. of common building materials - see chart:
Chart:
Combustion degree of building materials classifi ed according to the combustion degree of materials and
products (EN 730823)
A noncombustible
B uneasily combustible
C1 hardly combustible
C2 middle combustible
C3 easily combustible
Devices must be instalated in a safe way. When instaling you must respect corresponding project, safety and
hygienic orders according to:
• EN 061008 fi re protection of local devices and sources of heat
• EN 332000 surrounding for electric devices
5
ACCORDING TO EN 061008 ČL. 21
granit, sandstone, concretes,bricks, ceramic wallfacing tiles, plaster
akumine, heraklite, lihnos, itavere
leafy wood, plywood, sirkoklit, rare paper formica
fi breboards, solodure, cork boards, rubber,fl oor-coverings
wood-fi breboards, polystyrene,polyurethane, PVC