Balluff BAE SA-CS-027-YI-BP00,3 GS04 Betriebsanleitung Seite 43

Sensorverstärker
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BAE SA-CS-027-YI-BP00,3 GS04
IO-Link Sensor Amplifier
8
Interface (continued)
Index
Name
36
Device Status
37
Detailed Device
Status
40
Process Data Input
60
Setpoints BDC1
– Set-Point SP1
– Set-Point SP2
61
Switch Point BDC1
– Logic
– Mode
70
SIO Output Type
71
Debounce
– Delay On
– Delay Off
72
External Trigger
73
Display Settings
– Intensity
– Rotation
www.balluff.com
Subindex
Data type
UINT8
UINT16
1
UINT16
R/W
2
UINT16
R/W
R/W
1
UINT8
R/W
2
UINT8
R/W
UINT8
R/W
1
UINT16
R/W
2
UINT16
R/W
UINT8
R/W
Record
1
UINT8
R/W
2
UINT8
R/W
Value range
0 = Device OK
2 = Out of Specification
4 = Failure
0...4095
0...4095
0 = normal function
1 = inverted
1 = standard switching
function
2 = 2-point switching
3 = window function
4 = dynamic operation
1 = PNP N.O.
2 = PNP N.C.
3 = NPN N.O.
4 = NPN N.C.
5 = push-pull N.O.
6 = push-pull N.C
0...6500
0...6500
0 = inaktive
1 = teach line active
2 = fill level regulation
0 = 50%
1 = 100%
0 = normal alignment
1 = rotated by 180°
Comment
Device status
See events
Current process data, see
section 8.2
Switchpoint 1, see
section 7.4
Switchpoint 2, see
section 7.5
BDC1 configuration
Switching logic
Switching mode, see
section 7.6.1
Switching power amplifier
See sections 7.6.3 and
7.6.4
Switch-on delay × 10 ms
Switch-off delay × 10 ms
See section 7.6.2.
If bit 3 Local Parametriza-
tion in the Device Access
Lock parameter is set, the
External Trigger input is
active.
See section 7.7