Cleaning, Care & Maintenance
Disconnect from electricity supply, allow to cool before emptying the water from the Body, always use
fresh water when the kettle is to be used.
Always wash the Kettle Liner, Top Ring and Lid after every use. Wipe both exterior and interior of
the Body to remove any food residues, do not immerse the Body in water or clean with a pressure
washer.
Dry thoroughly after cleaning.
De-scaling
In hard water areas lime scale can build up within the appliance after prolonged use. For best taste and
extended appliance life, de-scale it regularly. Installation of a water filtration system is also recommended.
To de-scale the appliance.
1. Remove the lid and inner container first.
2. Pour a solution of de-scaler and water into the outer container.
3. Follow the manufacturer's instructions on the de-scale solution with reference to the length of time
required to soak, agitation, water temperature and on how to dispose of the solution safely.
4. Fill the outer container with clean water and turn the appliance On to flush out the system. Flush out
the system thoroughly to remove any de-scaler residue.
5. The appliance is now ready for use.
Note: Use a suitable de-scaler and always follow the manufacturer's
instructions.
BUFFALO recommend that this appliance is de-scaled every 3 months or more
frequently in hard water areas.
IMPORTANT: Failure to de-scale or maintain will invalidate your guarantee.

Technical Specifications

Model
Voltage
GH227
220-240V~
50/60Hz
Troubleshooting
Fault
The unit is not working The unit is not switched on
Indicator light comes
on but unit does not
heat up
4
GH227_ML_A5_v4_20201229.indb 4
GH227_ML_A5_v4_20201229.indb 4
Power
Current
300W
1.3A
Probable Cause
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Heating element has failed
Thermostat has failed
Dimensions
Capacity
H x Ø mm
5.7L
348 x 255
Solution
Check the unit is plugged in correctly and
switched on
Call BUFFALO agent or qualified Technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Weight
3.22kg