Connectors, switches, mounting brackets:
The single-cable multi-switch has the connections, switches and mounting
brackets shown.
4 Inputs for Universal Quattro LNB
2 Inputs for Wideband LNB 1
Rotary switch
Quattro / Wideband
Mounting bracket
equipotential bonding
connector
Subscriber output 1
Subscriber outputs 2
Mounting bracket
Trunk outputs for cascading
Equipotential bonding and mounting:
The device and the outer conductors of the coaxial cables must be connected
to the equipotential bonding. This serves to avoid dangerous overvoltages
(caution: fire/life hazard) according to EN 60728-11.
 Use the equipotential bonding connection at the device.
 Use, for example, a QEW earthing angle with SAK patch cables at the inputs
and CFA 7-01 earth connection blocks at the subscriber outputs of the
device.
 Mount the device on a flat surface. Use appropriate mounting screws and
the mounting brackets of the device.
RF installation:
 Use highly shielded coaxial cables with F connectors. Suitable cables and
connectors can be found in the current AXING at www.axing.com.
Quattro LNB:
 Set the rotary switch to Quattro.
 Connect the SAT inputs LV, LH, HV and HH of the multiswitch to the LNB of
your SAT reception antenna.
Wideband LNB:
The single-cable multiswitches can be used with wideband LNB with an
oscillator frequency of 10.4 GHz.
 Set the rotary switch to WB.
 Connect the first wideband LNB to the left connectors V and H.
 Connect the second wideband LNB to the right connectors V and H.
Terrestrial:
 Feed the output signals of a terrestrial amplifier or a CATV amplifier into the
terrestrial input.
Subscriber outputs
 Connect the subscriber outputs of the multiswitch to the antenna wall
outlets.
Outputs and user bands*:
The SES 5216 has two subscriber outputs. At each of these, 16 user bands
are available. An alternative user band assignment for CATV networks up to
1218 MHz is also possible (this must be ordered at the purchase).
2 Inputs for Wideband LNB 2
For receivers according to EN 50607, all 16 user bands can be used.
Terrestrial input
UB 1
975 MHz
UB 2
1025 MHz
UB 3
1075 MHz
UB 4
1125 MHz
Mounting bracket
UB 5
1175 MHz
UB 6
1225 MHz
UB 7
1275 MHz
DC connector
UB 8
1325 MHz
Eight user bands can be used for
EN 50494 receivers.
 Assign each user band only once.
Mounting bracket
 Use programmable single-cable antenna wall outlets SSD 6-xx for
interference-proof operation.
 For multi-tuner devices (Twin or Quatto), assign the appropriate number of
user bands to the antenna wall outlet.
 Connect the user band with the highest frequency (UB 16) using the
shortest cable.
Coax
Equipotential bonding
EN 50607
EN 50607
SAT TV
SAT TV
UB13
UB14
UB15
EN 50607
EN 50607
SAT TV
SAT TV
UB9
UB10
UB11
EN 50607
EN 50607
SAT TV
SAT TV
UB5
UB6
UB7
EN 50607
EN 50607
SAT TV
SAT TV
UB1
UB2
UB3
EN 50494
EN 50494
SAT TV
SAT TV
UB5
UB6
UB7
EN 50494
EN 50494
SAT TV
SAT TV
UB1
UB2
UB3
UB 9
1375 MHz
UB 10
1425 MHz
UB 11
1475 MHz
UB 12
1525 MHz
UB 13
1575 MHz
UB 14
1625 MHz
UB 15
1675 MHz
UB 16
1725 MHz
* Customised user band configuration
Wideband-LNB
EN 50607
EN 50607
SAT TV
SAT TV
UB16
EN 50607
EN 50607
SAT TV
SAT TV
UB12
EN 50607
EN 50607
SAT TV
SAT TV
CFA 7-01
UB8
EN 50607
EN 50607
CFA 11-00
SAT TV
SAT TV
UB4
EN 50494
EN 50494
SAT TV
SAT TV
UB8
EN 50494
EN 50494
SAT TV
SAT TV
UB4
Cascading:
 If you do not connect any further single cable multiswitches, then
terminate the cascade outputs at the bottom of the device with
DC-decoupled 75 Ohm terminating resistors. (e. g. CFA 11-00 not
included in delivery).
Up to three single cable multiswitches can be connected to one cascade.
 Connect the outputs of the single cable multiswitch with the inputs of
the next single cable multiswitch units.
 Use F/F Quickfix adapters CFA 4-01 or highly shielded coaxial cables with
F-connectors (not included).
 Terminate the outputs of the last device with DC-isolated 75 Ohm
terminating resistors (e. g. CFA 11-00 not included in delivery).
possible.
Power supply:
The single-cable multiswitch is supplied via an external power supply
unit SZU 99-06 (not included in the delivery). This power supply unit
also supplies the connected LNBs and any cascade modules that may be
connected.
The total supply current via the DC connection must not exceed 1 A.
Check that the current consumption of all connected components does
not exceed 1 A. If necessary, connect another external power supply unit
SZU 99-06 to a cascade unit.
2 x SCO 2-10
Application example:
DVB-C
16 TV devices with tuners which support
subscriber output 1. 8 TV devices with tuners which support
connected to subscriber output 2 (for further application examples, please
refer to www.axing.com). If different receivers (EN 50607/EN 50464) are
QEW 5-06
connected to one subscriber output, ensure that the user bands are assigned
correctly.
5 × SAK 21-02
Single cable or legacy mode:
SES 5216-06
The single-cable multi-switch automatically detects which mode the
connected receiver requires and provides the appropriate signal (in single-
cable mode the user bands, in legacy mode the polarisation level). The
detection is performed separately for each subscriber output.
The legacy mode cannot be used with programmable antenna wall
SZU 99-06
outlets SSD 6-xx!
The legacy mode cannot be used with wideband LNBs!
To prevent a receiver which is not suitable for single-cable operation
switching the subscriber output to legacy mode, we recommend
programmable SSD 6-xx antenna wall outlets.
EN 50607
are connected to
EN 50464
are

Werbung

loading