Herunterladen Diese Seite drucken

Transport, Handling And Storage; Technical Specifications - La Buvette LAKCHO 2 Montageanleitung

Werbung

Liability :
The company LA BUVETTE is released from any and all liability :
- If the transport, handling and storage instructions have not been observed
- If the device is used for other purpose than that which is originally intended.
- If the installation, operation and maintenance instructions described in this document are not observed.
- If the installation and starting up procedures have not been performed by an authorised specialist.
- If technical or functional modifications have been performed without LA BUVETTE's authorisation.

Transport, Handling and Storage :

The material shall be inspected immediately upon receipt for any damage that might have occurred during its
transportation. Damage shall be reported to the carrier within the specified period.
Note: If the delivered material will be installed later, store it in a dry place and protect it against shocks and other
exterior influences (humidity, frost, etc.)
Safety :
Disconnect the power supply during the installation and all later interventions
The device is only designed for use in a 24 V AC installation
Do not operate the device without water
Risk of burns in case of direct contact with the heating element

Technical Specifications :

180 W heating element
Voltage: 24 V AC
Optimum operating pressure: 3 bars
Maximum operating pressure: 6 bars
Installation :
The device must be installed by an authorised specialist.
Switch off the power supply before each intervention.
All electrical connections are protected by sealed boxes that are adapted to the installation
environment (mini IP 54). They shall be securely fastened by appropriate means such as screws and plugs.
The use of glue is inadequate.
The cable grommets protect the cables from tearing and torsion.
Use approved cables (H07 RN-F) with a section that is compatible with the cable glands.
The section of the wires (mm²) must be compatible with the power produced. See table P.5 to determine the
section of the wire to be used.
The device must be connected to a 230 V/24 V transformer. Use our transformers of the A501, A502, A503,
A504, A505 series.
Install the electrical protection devices (FUSES) required by the maximum power of the installed transformer
(see table on page 6 of these instructions or the instructions of the LA BUVETTE transformers).
The device is preferably mounted on our LA BUVETTE A570, A572, A573, A574 PE stand models.
In case of mounting on a concrete stand, it must be NF certified with a maximum diameter of 300 mm +/- 3.
Make sure the cut is clean.
Strictly follow the installation procedure of the metal inserts.
To protect the water lines from frost, they have to be buried at least 1 m underground (the indicated depth might vary
according to the geographical area).