Herunterladen Inhalt Inhalt Diese Seite drucken

Casanoov TANKER C600 Handbuch Seite 9

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 41
EN
Rack Fixing
Set the gear-motor on manual unlocking. Wide open the gate's door.
Place the rack: place the first element on the pinion and fix it with screws to the gate.
Move the door manually and repeat the procedure with the other elements using adistance spacer to
ensure the correct position from the rack.
It is advisable to leave 2mm between the rack and the gear to avoid the gate resting on the gear-motor.
Installation of limit magnet
There are 2 limit magnet supplied. Note there is a left hand (default setting: open limit in blue magnetic)
and a right hand magnet. (default setting: closelimit in RED magnetic)
The magnet should be installed one at either end of the rack.
To install the magnet in the correct position, open the clutch door and press the 'CLOSE' button on the
remote. The motor will run but will not drive the gate. Close the gate manually and adjust the limit
magnet to contact the toggle switch and switch the motor off at the desired gate position. To adjust the
stop position of the gate when it is open, press the 'OPEN' button, manually open the gate and adjust
the other limit magnet to contact the toggle switch and switch the motor of When you are satisfied the
limit magnet are in the correct positions, tighten the screws in the limit magnet to clamp them to the
rack, close the clutch door and using the remote control check the gate opens and closes to the desired
positions. Adjust the limit magnet if necessary.