Protection against electric shock
Protections rating
Operating conditions
Storage conditions temperature
Storage conditions humidity
Maximum variation of the light
output over the treatment area
Operating pressure
Optical exposure
Maximum optical energy
Optical homogeneity
Pulse duration
Pulse repetition time
Pulse sequence
Optical spectrum
Troubleshooting
Problem
The device/adapter
becomes warm during use.
Class II
IP 30 (EN 60529)
Temperature: 5 °C to 35 °C
Relative humidity: 15% to 90% (non condensing)
-25° to +70°C
Less than 90% (non condensing)
<20%
700hPa-1060hPa
2.4-6.5 J/cm2 (between 560 and 1400 nm)
23 J
Max. +/- 30% deviation from average optical exposure in
treatment area
1-2.5 ms
0.9 - 3.5 seconds
Single pulse
Between 560 and 1400 nm
Possible cause
It is normal for the device and
adapter to become warm (but
not too hot to touch) during
use.
The fan is not working.
The cooling airflow of the fan
is blocked by hands or a
towel.
Solution
Use the device in a slightly cooler
environment and/ or let it cool down
before continuing use.
Check if the attachment is well
connected. Clean the connectors on the
attachment if needed. In case the
attachment is well connected and it is
possible to produce flashes with the
device, contact the Consumer Care
Center in your  country, your Philips
dealer or a Philips service center.
Make sure the cooling airflow of the fan
is unblocked.