Herunterladen Diese Seite drucken

Honeywell AMK 4 S G3 Montageanleitung Seite 2

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical data
SURFACE MOUNT MAGNETIC CONTACT AMK 4 S G3 zone types,
tamper protected.
Operating distance:
: 29 mm, ± 5 mm
Permitted operating voltage : max. 40 V DC
Switching current
: max. 500 mA
Contact capacity
: max. 6 W or 6 VA
Transition resistance
: max. 0,15 Ohm
Breakdown voltage
: > 250 V
Connecting cable
: LIYY 4 x 0,14 mm² Cu tinned,
suitable for LSA insulation
Internal conductor
: blue
Dimensions cable
: ø 3,2 mm, L 2 m
Contact-housing dimension : 146 x 50 x 16,5 mm
Metal hose
: ø 6 x 9 mm steel
galvanized, PVC coated
Magnet
: ø 12 x 55 mm AlNiCo 5, axial polarized
Magnet-housing dimension : 66 x 40 x 35 mm
Housing material
: Polyamid GF
Colour
: grey
Temperature range
: - 40 °C to + 70 °C
Protection class
: VdS-environmental class III, IP 67,
EN-environmental class IIIA
Extend of Delivery
• 1 shutter contact with protecting hose
• 1 shutter magnet
• Mounting instructions
Description
Normally the surface mount magnetic contact is installed at rolling gates,
sliding gates, sweeping gates and so on.
The contact housing is mounted on the ground. The surface at the place of
installation must be smooth. Only non-ferromagnetic screws must be used for
mounting the surface mount magnetic contact.
The design of the unit protects the circuit against weather and mechanical
influences from vehicles with latex tires. The connecting cable (4 wires) is
protected by a metal hose which is PVC coated.
The position of the magnet housing is given by the contact housing. Make
sure that the magnet housing fits to the marking on the contact housing. The
prefered mounting distance between contactand magnet-housing is shown in
the schematic of distance. Ferromagnetic parts disturb the magnetic field of
the surface mount magnetic contact.
The area of approach and removal changes in the schematic of distance. Find
the normal switching area by testing. The magnet should be fixed in the middle
of the normal switch area on principle.
One part of the surface mount magnetic contact is fixed at a door. When the
door is closed, a small movement can still exist. Take care of this tolerance.
When mounting is complete, the magnetic contact's electrical switching
function must be checked (e.g. using an ohmmeter or continuity tester).
CAUTION: The magnet loses a part of its field strength if it gets very hot
or through mechanical influences. This also can happen, if the
magnet is moved close to the area of another magnet.
Honeywell Commercial Security
Novar GmbH
Johannes-Mauthe-Str. 14
72458 Albstadt, Germany
www.honeywell.com
info.security.de@honeywell.com
Certificate holder:
LINK GmbH, Bahnhofsallee 59-61, 35510 Butzbach, Germany
Mounting Instructions
AMK 4 S G3
Item no. 031056
MA0002141
3418
Mounting
Magnet-housing
Contact-housing
Schematic of distance
Operating
Tol.
distance (mm)
[mm]
A
29
± 5
B
40
± 10
C
10
± 2
Minimum operating distance: 24 mm
Tolerance in x:
max. ± 3 mm
Connecting cable
Connection
1
1
2
4
2
3
Before connecting, the wires must be electrically checked !
G 109 046, Kl. C
D
Technical changes
without prior notice
EN 50131-2-6, Grad 3
GB
Safe area
A = approach / make distance
B = removal / break distance
C = prohibited area
switching contact sabotage protection
possible
3
4

Werbung

loading

Diese Anleitung auch für:

031056