Herunterladen Diese Seite drucken

Honeywell EMK 46 S G3 M Montageanleitung Seite 2

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical data
Recess mount magnetic contact EMK 46 S G3 M for differential lines,
sabotage-proof
For front-end recess mounting into ferromagnetic materials
Operating distance
:
12 mm, ± 3 mm
Permitted operating voltage :
max. 40 V DC
Switching current
:
max. 500 mA
Contact capacity
:
max. 6 W or 6 VA
Transition resistance
:
max. 0,15 Ω
Breakdown voltage
:
> 250 V
Connecting cable
:
LIYY 4 x 0,14 mm² Cu tinned,
suitable for LSA insulation
Cable colour outside
:
white
Internal conductor
:
blue
∅ 8 x 31 mm with recess mount flange EF 8/20
Dimensions contact
:
(drilling diameter 20mm)
∅ 3,2 mm
Dimensions cable
:
Cable length
:
10 m
∅ 6 x 19 mm neodymium, axial polarized,
Magnet
:
in ∅ 8 x 20 mm plastic sleeve with
recess mount flange EF 8/20 (drilling diameter 20mm)
Housing material
:
S-B oder A-B-S, flange PA6 GF 30
Colour
:
white
Temperature range
:
- 40 °C to+ 70 °C
Protection class
:
VdS-environmental class III, IP 67,
EN-environmental class IIIA
Extend of Delivery
• 1 magnetic contact ∅ 8 x 31 mm with 1 flange EF 8/20
• 1 magnet ∅ 6 x 19 mm neodym in plastic sleeve ∅ 8 x 20 mm mit
1 flange EF 8/20
• Mounting instructions
Description
Magnetic contact and magnet must be mounted in a front-end-position in
window frames - casements, doors- and doorframes.
CAUTION:
The EN grade 3 recess mount magnetic contact EMK 46 S G3 M
has been developed for the mounting into ferromagnetic
materials.
When installing the snap-in metal recess mount flanges
EF 8/20, a material thickness of 0,5 - 2,3 mm is permitted.
After the mounting is finished, an electrical continuity check must be carried
out (ohmmeter).
Too much force on the housing can harm the glass body of the reed contact.
Therefore be careful when mounting the contact.
Mounting
Snap-in metal recess mount flange
EF 8/20 at the contact and
magnet housing
Honeywell Commercial Security
Novar GmbH
Johannes-Mauthe-Str. 14
72458 Albstadt, Germany
www.honeywell.com
info.security.de@honeywell.com
Certificate holder:
LINK GmbH, Bahnhofsallee 59-61, 35510 Butzbach, Germany
Mounting Instructions
EMK 46 S G3 M
Item no. 030286.10
MA0002137
1519
31
Contact
Schematic of distance
Magnet
Contact
Min. mounting distance:
3 mm
Min. operating distance:
9 mm
Tol. in x:
± 3 mm
Connection
Connecting cable
1
4
2
3
Before connecting, the wires must be electrically checked !
G 109 046, Kl. C
D
Technical changes without
prior notice possible
EN 50131-2-6, Grad 3
GB
0,5
Magnet Neodym
11,65
∅ 6 x 19 mm
20
Magnet
+ X
A
B
Y
Safe area
Ruhebereich
A = approach / make distance
A = Näherungs-/ Einschaltabstand
B = removal / break distance
B = Entfernungs-/ Abschaltabstand
- X
Operating
Tol.
[mm]
distance (mm)
A
12
± 3
B
15
± 3
1
3
switching
contact
4
2
sabotage protection

Werbung

loading

Diese Anleitung auch für:

030286.10